5.0 Installation Procedure
Install the hold down bolts to secure Gamma Bracing Frame to the substrate. A
socket drive extension can be positioned through the access hole in the lower
trellis to enable the hold down bolt to be tightened.
Fully tighten the hold down bolts
Install the 12g x 40mm Tek screws in each Bracket. (Provided)
Quantity of 8 screws per bracket. (Provided)
Install the 12g x 40mm Tek screws to the Gamma Bracing Frame. Pre punched
holes are positioned in the up-right sections and the top end cap of the Gamma
Bracing Frame provided.
The Gamma Bracing Frame is now fully installed and providing its structural
performance.