SLM Face Plate Installation
Remove the tape covering the opening on the front side
of the bottom cover to expose the string length meter.
Position the face plate assembly over the opening in the
bottom cover, and align the two countersunk end holes
of the face plate with the threaded attachment holes in
the front of the string length meter. With the two flat head
machine screws, secure the face plate assembly to the
string length meter.
To check for proper alignment, lift the top clamp of the
face plate assembly and insert a section of racquet
string at least 12 inches long into the entrance hole of the
face plate. Continue feeding the string section into the
string length meter, until it appears through the exit hole.
If the entrance or exit holes appear to be blocked, loosen
the attachment screws and adjust the position of the
face plate assembly until the section of string exits the
face plate. After the face plate is properly aligned,
tighten the flat head screws.