background image

a. 

Turn off PCB power for two seconds 

b.  Weight unit conversion in calibration 

c. 

Select the digit in 0, 1, 2, …, 9, 0 sequence in calibration

 

TARE 

a. Tare 

b.  Make confirmation in calibration 

ZERO 

a. 

Zero setting within allowable range 

b.  Clear the accumulate value when push the [ZERO] and [ON] button in same 

time 

c. 

Select the digit in 9, 8, 7, …, 0 sequence in calibration 

 

4. Operation 

4.1 Power-on 

a. Adjust the support feet to make sure the scale is under level state, it must be used 

in non-vibration condition. 

Note: Be sure that the protecting cardboard is removed before operation. 

b. While using AC power, connect it with the power adaptor and tighten the 

attached knob. At the same time, if will charge the storage battery. When charging 

finish, disconnect the adapter and seal the knob. 

c. Press [ON], firstly, it will display a version number after giving out a sound of 

 

- 3 -

Summary of Contents for GMB-803

Page 1: ...GMB 803 806 815 830 Waterproof Digital Scale Operation Manual Version 2 2 Gamma Scale Tel 905 455 8333 Fax 905 455 0658 E mail info gammascale com Website www gammascale com...

Page 2: ...ting temperature 25 C 50 C 1 8 Relative humidity no more than 100 1 9 Water proof design IP66 IP67 1 10 Power supply 9V 800mAAC adapter only 1 11 Display 6 digits 0 56 inch LED 1 12 Display stability...

Page 3: ...value warning 2 6 Units g or Kg Lb 2 7 Low battery voltage indicating 2 8 Voltage saving display mode 2 9 Auto shut off 2 10 Key beep sound selection 2 11 simple rectifying 3 Operation Keys ON a Turn...

Page 4: ...8 7 0 sequence in calibration 4 Operation 4 1 Power on a Adjust the support feet to make sure the scale is under level state it must be used in non vibration condition Note Be sure that the protecting...

Page 5: ...hen the indicating NET light on zero setting doesn t work 4 3 Tare Place the container or packing material on platter then press TARE it will display 0 000 and the indicating NET turns on Press TARE a...

Page 6: ...in several minutes 5 2 If it automatically shut off as soon as it is turned on with DC power it means its battery voltage is seriously low at this time charge the battery at once 5 3 If the working ti...

Page 7: ...ok and battery being charged properly With AC adaptor plugging in Scale display should always stay on 0 000 never go to sleeping mode do not display D How to tell battery been fully charged With AC a...

Page 8: ...ction it must be used under high non vibration conduction 6 2 While weighing place the load in the center of the platter as far as possible 6 3 Never use high corrosive solvents to clean it 6 4 Do not...