background image

If you choose to vary from these instructions your warranty will be impaired

3

DIAGRAM 1

STEP 1 

BACK WALL

Join the 4 sheets 

C

 together with 2 fixings through the overlapping ribs, making 

sure the ends of the sheets are flush. Cap the sheeting with the 3000mm 
'U' channels 

F

.

Fix the channels through the end ribs and every second rib in between. Make sure 
you put at least one fixing per sheet up through the underside of the  channel into 
the pan of the sheet.

STEP 2 

ROOF

Join the sheets 

D

 together the same as the back wall. Cap the sheeting with the 

3000mm 'U' channels 

F

. Fix the channels at every second rib but not the corners at this 

stage. Place the short flange of the first 'L' flashing 

M

 on top of the rib at one end. 

Make sure the ends are flush with the sheeting (diagram 1) and put one  
fixing in the centre to hold the 'L' flashing. Fix the corners through  
the channels and one more between the corner and the centre  
fixing. Perform the same at the other end.
Fit the ridge beam 

R

 to 1 roof panel only. 

Fix through the ends and up through the  
internal flange on the underside.

GALVO TIP

Put extra fixings in for  

high wind areas, particularly  

on the underside.

YOU WILL NEED

8 x 1200mm x 780mm sheets 

4 x 3000mm 'U' channels

4 x 1200mm 'L' flashings

1 x 3000mm long ridge beam

D

F

M

R

YOU WILL NEED

4 x 1830mm x 780mm sheets 

2 x 3000mm 'U' channels with ends cut

C

F

F

F

C

R

M

M

F

F

D

Summary of Contents for GVO 3023

Page 1: ...riveter Tape measure Ladder Non slip gloves good shoes and goggles A set of helping hands CALL 0508 454 873 for an installer near you Some parts have sharp edges and should be handled very carefully W...

Page 2: ...M Q B F J N R S C G K O D L P ASSEMBLY OVERVIEW These instructions are designed to guide you though the process of building your new garden shed It is a simple process of joining sheets together befo...

Page 3: ...t every second rib but not the corners at this stage Place the short flange of the first L flashing M on top of the rib at one end Make sure the ends are flush with the sheeting diagram 1 and put one...

Page 4: ...age for 2nd door Attach 1770mm Z door jamb to 2nd door onto the on the same side as the door plate This Z serves as a weather flashing between the doors when they are closed 150MM A J L O P N J L P L...

Page 5: ...may need to cut or bend the flange at the bottom and the top of the Z if it catches on the door jamb when opening or closing see AFTER DIAGRAM 1 BEFORE YOU WILL NEED 2 x Z Door braces Fixings Q P NARR...

Page 6: ...ts with the 3000mm channels F Use the door spacers K to make sure the door fits the gap they sit on top of the Z door jambs N see diagram 1 Drill and fix rivet or screw the channels at every second ri...

Page 7: ...he pan into the top channel of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through...

Page 8: ...nt or act of God including weather b The warranty shall cease and the Supplier shall thereafter in no circumstances be liable under the terms of the warranty if the workmanship is repaired altered or...