INSTALLATION

 

 
Avoid common installation errors 

 

Incorrect supply pipe size installed.  

Non-compliance to Australian Standards. 

Water pressure not tested before installation  

 

Lines not flushed before installation. 

No access for service. 

Valve not commissioned properly.

 

 

 

1.  Mount face plate 

The stainless steel face plate is always 
mounted flush to the wall.  

Mount supplied Galv Inwall box into the wall  
1 or 2mm below the finished wall surface.  

The Galv Inwall box can be fixed to a masonry 
wall or wall frame using screws suitable for the 
fixing method. (Fasteners to be supplied by 
installer). 

We recommended that all cabling is fed 
through 25mm conduit to make servicing and 
replacment easier. 

Apply a thin bead of silicon on the edge of the 
wall cut out.

 

Fit the face plate to Galv Inwall box with 
supplied screws, use supplied snake eye key.

 

If extension leads are required, please 
contact Galvin Specialised.

 

Do not force the faceplate to fit onto wall or 
attempt to dissamble components, as this 
could result in damage to sensor push 
button.

 

2.

 

Connect solenoid 

 

Connect solenoid assemblies to the outlet as 
shown and in accordance with AS/NZS 3500. 

 

Ensure that the solenoid is installed in the 
correct direction (the arrow on the solenoid body 
must align with the direction of water flow).

 

 

Line strainers are supplied attached to the 
solenoid valves. Removal of these strainers may 
void the warranty.  

Ensure no thread tape, copper swarf, sand or 
other debris enters and fouls the solenoid 
valve. 

 

Make sure solenoid valve is orientated such 
that the electrical wiring is not twisted and 
connectors are easily accessible.

 

 

Note: Refer to solenoid operating instructions 
manual for installation and service maintenance

Summary of Contents for Flowmatic Safe-Cell

Page 1: ...is a 24V AC electronic control system allowing connection of up to 5 button inputs and 5 solenoids Depending on the settings programmed the solenoids will open for a specific time once the appropriat...

Page 2: ...ange of installation types and surfaces it is important that surfaces which fixtures are mounted to are flat and free from defect This is especially important for our Flowmatic Safe Cell range where s...

Page 3: ...er wall mounted or hub mounted Outlets are not supplied and must be ordered separately Typical Installation Cut out details for face plate The stainless steel face plate assembly should be mounted flu...

Page 4: ...he wall cut out Fit the face plate to Galv Inwall box with supplied screws use supplied snake eye key If extension leads are required please contact Galvin Specialised Do not force the faceplate to fi...

Page 5: ...unting feet supplied with the control module to the back of the controller module box Measure the holes between centres as shown in pre installation page of control module dimensions Find a suitable p...

Page 6: ...ads please contact Galvin Specialised Do not cut the leads If the leads are too long it is recommended that any excess is coiled up and clipped to the wall 6 Connect power supply and check for correct...

Page 7: ...electrical connections replace solenoid valve Water or structural damage to electrical components Replace damaged electrical components Incorrect connections Check all connections Damage to sensor le...

Page 8: ...expressly and is the only warranty given by the Galvin Engineering Pty Ltd With respect to the product Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Lt...

Reviews: