background image

 

Version 2, 18 December 2020, Page 

12

 of 

12

 

Maintenance Instructions

 

Solenoid Valve: 

 

 

Turn the water supply off and activate the push button to drain as much water from the installation 
as possible, and then turn the power off at the GPO. 

 

Depending on the location of the solenoid valve it may be more convenient to remove the solenoid valve 
completely from the installation to service it.  

 

The solenoid may be disassembled and checked for debris and cleaned to avoid potential damage to the 
diaphragm. Please take note of the location of the components and reassemble in the correct order, as 
there is a spring in the housing that may inadvertently spring out. 

 

Service or replace the solenoid and re-install into the line. Push the power plug from the sensor back 
onto the solenoid. 

 

It is recommended that the line strainer be serviced and cleaned at this stage to ensure that dirt and grit 
isn’t restricting the flow 

 

Ensure the bypass tap on the valve is in the closed position 

Push Button, Face Plate, Control Module and Power Transformer 

 These items are non-serviceable products. If damaged they must be replaced.   
 If there appears to be any problems with these items please contact Galvin Engineering. 
 

Note: Before attempting to replace any of these items check that you have access to re-run the 
connection leads. If you do not have access or you have any doubts, please contact Galvin 
Specialised for advice before commencing replacement. 

 
 

WARRANTY

 

The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty 
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. 
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but 
not limited to the implied warranties of merchantability and fitness for a particular purpose. 
 
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download 
from www.galvinengineering.com.au  Galvin Engineering Pty Ltd expressly warrants that the product is free 
from operational defects in workmanship and materials for the warranty period as shown on the schedule in 
the manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any 
defective products manufactured by Galvin Engineering without charge, so long as the terms of the 
Manufacturer’s warranty are complied with. 
 
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for 
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or 
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other 
property which is damaged if this product does not work properly, other costs resulting from labour charges, 
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, 
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty 
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or 
alteration of the product.

 

 

Summary of Contents for Safe-Cell TZ-FLOWTPANMDT

Page 1: ...utton inputs and up to 2 solenoids single solenoid only for flushing units Controller is pre programmed and ready to use The solenoids will open for a specific time once the appropriate button is pres...

Page 2: ...quired to minimise ligature points and areas for concealment of contraband In addition to ensuring the products are fitted securely and in accordance with the following instructions consideration shal...

Page 3: ...mend 300mm from the centre of the outlet and at a suitable height or to project specification Cut out details for face plate Faceplate to suit wall thickness between 30mm to 240mm Ensure the cut out d...

Page 4: ...nyloc nuts and apply a thin bead of silicon on the edge of the wall cut out If extension leads are required please contact Galvin Engineering Do not force the faceplate to fit onto wall or attempt to...

Page 5: ...ic nylon or electrical parts and seals and will void the warranty Note Controller must be mounted away from any moisture or potential water splashing 4 Mount control module Attach the control module t...

Page 6: ...red please contact Galvin Specialised Do not cut the leads If the leads are too long it is recommended that any excess is coiled up and clipped to the wall 6 Connect power supply and check for correct...

Page 7: ...scanning the first thing to come up in available devices will be a Mac address that looks like this example AB EC 69 57 34 02 This will eventually change to the name of the device which is from factor...

Page 8: ...ory parameters will be downloaded to the app The Get log button will pop up the log data screen The Presets button will list all saved presets Drop Down menus First menu from left is to select the typ...

Page 9: ...p down menu The PB2 controller can be used for showers basins and pans Depend of the feature selection setting slides will appear e g there is only Run time to be set for basin Run and Lockout times f...

Page 10: ...nd Hygiene flush for full flush channel 2 and press Upload 10 Settings for shower PB2 controller is capable of controlling two buttons and two showers solenoids Select channel to be changed Select des...

Page 11: ...ck electrical connections Replace solenoid valve Water or structural damage to electrical components Replace damaged electrical components Incorrect connections Check all connections Damage to sensor...

Page 12: ...the only warranty given by the Galvin Engineering Pty Ltd With respect to the product Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specific...

Reviews: