5. Fit handle 

 

Ensure the spindle is in the closed position 
and firmly press the CliniLever

®

 lever 

handle onto the spindle in the desired 
orientation. 

 

Check operation of CliniLever

®

 lever 

handle. They should turn freely for a full ¼ 
turn. 

 

Secure the handle in position using the 
supplied washer and stainless steel cap 
screw. 

 
 
 
 
 
 
 
 
 
6

.

 Fit water temperature indicator & testing 

 

Once CliniLever

®

 lever handle is secure; fit the 

appropriate water temperature indicator.

 

 

Once temperature indicator is fitted, check the 
operation of the unit and inspect for any leaks.

 

 

 

TROUBLESHOOTING

 

PROBLEM 

CAUSE 

RECTIFICATION 

Taps are dripping water 

Jumper valves are worn or damaged 

Replace jumper valve 

Ceramic discs are worn or damaged 

Remove and inspect SBA. 
Remove debris and/or  
replace SBA if damaged. 

Tap seat is damaged 

Refurbish tap seat using a 
reseating tool. 

Water is leaking from spindle 

O-ring on jumper valve spindle is 
damaged or worn 

Replace o-ring 

Water is not flowing from tap 

Water is turned off 

Turn water on 

Aerator or flow regulator is blocked by 
debris 

Remove aerator and/or flow 
regulator from tap and remove 
debris. Install an inline strainer. 

Obstruction on spout 

Check if there are obstructions 
hindering the water flow in the 
spout and take it out. 

Spindle is difficult to turn  
(jumper valve) 

Build up of scale on spindle, spindle 
worn or o-ring has been damaged 

Remove jumper valve, clean and 
regrease. Replace o-ring. 
Complete SBA may need to be 
replaced. 

Handle is loose 

Screw has come loose 

Tighten handle screw 

Flange does not screw down 
onto basin/sink surface 

Tap bodies are set too far out 

Re-position tap bodies and breach 
piece 

 