Product Installation Guidelines
Document No.: 001.00.10.05
Version 1, 7 April 2022, Page
4
of
5
5. Fit handle
−
Ensure the spindle is in the closed position
and firmly press the CliniLever
®
lever
handle onto the spindle in the desired
orientation.
−
Check operation of CliniLever
®
lever
handle. They should turn freely for a full ¼
turn.
−
Secure the handle in position using the
supplied washer and stainless steel cap
screw.
6
.
Fit water temperature indicator & testing
−
Once CliniLever
®
lever handle is secure; fit the
appropriate water temperature indicator.
−
Once temperature indicator is fitted, check the
operation of the unit and inspect for any leaks.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Taps are dripping water
Jumper valves are worn or damaged
Replace jumper valve
Ceramic discs are worn or damaged
Remove and inspect SBA.
Remove debris and/or
replace SBA if damaged.
Tap seat is damaged
Refurbish tap seat using a
reseating tool.
Water is leaking from spindle
O-ring on jumper valve spindle is
damaged or worn
Replace o-ring
Water is not flowing from tap
Water is turned off
Turn water on
Aerator or flow regulator is blocked by
debris
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Obstruction on spout
Check if there are obstructions
hindering the water flow in the
spout and take it out.
Spindle is difficult to turn
(jumper valve)
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Handle is loose
Screw has come loose
Tighten handle screw
Flange does not screw down
onto basin/sink surface
Tap bodies are set too far out
Re-position tap bodies and breach
piece