PRE-INSTALLATION

 - 

MOUNTING DETAILS

 

Wall body 

 

Wall body must be G5/8” FI and body 
should  be  between  0  and  15mm 
behind the finished wall surface. 

 
Wall spud 

Wall spud must be ½” BSP MI and protrude 
from the finished wall by no more than 15mm

 

 
 
 

 
 

 

 
 
 

Note: In some situations, a male thread 
connection on the tap may be more suited. If so, 
please contact us on 1300 514 074 

 

Note: Before installation, all lines must be flushed.  We 
recommend that a line strainer be installed prior to taps 
to eliminate any foreign material.

 

 

 
 
 
 
 
 
 