background image

 

© Galvin Engineering Pty Ltd 

 

Product Installation Guidelines 

Document No.: 001.00.10.05 

 

Version 1, 7 April 2022, Page 

3

 of 

5

 

 

INSTALLATION

 

IMPORTANT: Galvin Engineering products must be installed in accordance with these installation instructions 
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical 
supply conditions must also comply to the applicable national and/or state standards. Failing to comply with 
these provisions shall void the product warranty and may affect the performance of the product.

 

 

 

1. Fit O-ring 

  Before fitting spout to wall spud, ensure the 

o-ring is in place as shown

 

2. Fit Spout 

 

Screw spout clockwise onto wall spud as 
shown. 

 

Ensure thread tape is used. 

 

 

 
3

Fit Spindle Assembly 

 

Remove handle and flange from cartridge 
assembly.  Unscrew  the  ¼  turn  ceramic 
head  part  from  the  threaded  sleeve 
assembly  and  screw  ceramic  cartridge 
into the valve body by hand,  tighten using 
a 17mm spanner. 

 

Refit threaded sleeve and spindle. 

 

The ¼ turn ceramic head part MUST be 
fitted into the wall body prior to refitting 
the  threaded  sleeve  and  spindle.  DO 
NOT  tighten  cartridge  by  using  the 
spindle or the threaded sleeve. 

  

 
4

Fit Wall Flange

 

 

Ensure o-ring is fitted to the bottom of the wall 
flange, and then hand-tighten the wall flange 
onto the threaded sleeve.

 

Reviews: