background image

Monomando Alto con Contra de Push / 

Tall, Single Control Faucet for Wash Basin 

with Push Drain

EP-915 

Mangna DX

   INSTALLATION GUIDE

   GUÍA DE INSTALACIÓN

1-02-2928-2

Para el correcto funcionamiento de 
este producto, la presión mínima 
es de (0,6 kg/cm²) 8,53 PSI.

5 m

 6 m

 7 m

7,11
8,53
9,95

0,5
0,6
0,7

For the correct operation of this 
product, the minimum pressure is 
(0,6 kg/cm²) 8,53 PSI.

Cada metro de altura de 
su producto a la base 
del tinaco equivalen a 
(0,1 kg/cm²) [1,42 PSI].

Every meter of height of 
your product to the base 
of the water tank (0,1 
kg/cm²) [1,42 PSI] 
equivals.

PSI

Altura (h)

 

kg/cm²

Height (h)

[email protected]

Original  Parts:

Consultancy and Technical

01(55)53339431

01800 909 2020

01 (55) 53 33 94 00 

Refacciones Originales:

Asesoría y Servicio Técnico:

Ext. 5068, 5815 y 5913

Service:

 53 33 94 21 

01 800 890 0594 

[email protected]

ADVERTENCIA

 / WARNING

Para disminuir el riesgo de lesiones o daños a la propiedad, lea todas las instrucciones antes de instalar el 
producto. Utilice gafas de seguridad. En obras de construcción, instalación, modificación, ampliación y 
reparación deben cumplir con el  reglamento de construcción y obras de su localidad. 
El producto ilustrado puede sufrir cambios de aspecto como resultado de la mejora continua a la que  está 
sujeto.

Agradecemos su elección por los productos HELVEX. 
Estamos seguros de que su confiabilidad por el producto excederá sus más altas expectativas, cuya 
funcionalidad, estética, durabilidad, respaldo integral y alta calidad le otorgarán plena satisfacción por años, 
reflejando el compromiso con la calidad,  innovación y el medio ambiente que forman parte de Helvex.

Thank you for choosing HELVEX products.
We are confident that the product reliability will exceed your highest expectations. The functionality, 
aesthetics, durability are at its highest quality! The comprehensive support will grant full satisfaction for years, 
reflecting our commitment to quality, innovation and the environment as part of Helvex.

To reduce the risk of injury or property damage, read all instructions. Before installing the product, please 
remember to use safety glasses. In construction, installation, alteration, extension and repair, the rules of 
constructions must be applied. 

As result of continuous improvement, the product illustration may change in appearance. 

Esta guía de instalación  aplica al producto en cualquier acabado. / 

This installartion 

 guide applies to the product in any finish.

Requerimientos de

Instalación

Relación

 Altura Tinaco-Presión

Installation Requirements

Relation

 Tub Height-Pressure 

Herramienta Incluida en su Producto

/ Tools Included in your Product

Herramienta Requerida

/ Required Tools

perico

llave inglesa

teflón

wrench

teflon

tape

adjustable 

wrench

hexagonal 

wrench 1¼”

llave 

aereator 

service key

llave p/ 

llave allen

llave de  

mantenimiento  

key maintenance

hexagonal 1 ¼”

2 mm

aireador

2 mm allen 

wrench

Instalación General

hot

Caliente

cold

Fría

*55 cm

(21,6”)

*20,3 cm

angle stops

válvulas 

angulares 

NPT

(8”)

*Recommended 

*Medidas Recomendadas

(Nivel de Piso Terminado)

(Finished Floor Level)

/ General Installation

1

Cierre el suministro de agua.

 

/ Close the water supply.

Ubique y cierre las válvulas de suministro de agua.
Generalmente se encuentran debajo del lavabo. Si se trata de un 
reemplazo de grifo, quite el grifo viejo y limpie completamente la 
superficie del lavabo.

Locate and close the water supply valve.
Usually found under the sink. If it is a replacement faucet, remove 
the old faucet and clean the entire surface of the sink.

Summary of Contents for Mangna DX Mangna DX

Page 1: ... choosing HELVEX products We are confident that the product reliability will exceed your highest expectations The functionality aesthetics durability are at its highest quality The comprehensive support will grant full satisfaction for years reflecting our commitment to quality innovation and the environment as part of Helvex To reduce the risk of injury or property damage read all instructions Be...

Page 2: ...the faucet pipes and then to angle stops 14 NPSM angle stop not included Faucet Installation separador shank gasket empaque gasket Coloque el separador rondana y enrosque la tuerca para sujetar la salida Place the shank gasket stainless steel washer and tighten the nut to hold the faucet separador shank gasket rondana stainless steel washer nut tuerca 5 Abra el suministro de agua y purgue la línea...

Page 3: ...ría To open lift the handle to regulate the temperature turn left and right hotter to colder 13 caliente hot abrir open fria cold Abra el suministro de agua Opening the water supply Caliente hot cold Fría Revise que no existan fugas encima y debajo del lavabo Check for leaks up and down the lavatory Operación Operation 11 Desenrosque la cubierta y extensión superior coloque el inserto en el cuerpo...

Page 4: ...ded and clean water jet with a soft brush Mantenimiento del Aireador Maintenance Aerator Direccione el chorro hacia adelante atrás izquierda y derecha en cualquier ángulo Route the jet forward backward left and right at any angle 15 8 8 Se puede direccionar el chorro de agua presionando en cualquier punto del aireador como se muestra en la figura Can direct the jet of water pressing on any Aerator...

Page 5: ...salida Screw the aerator and place it back in the faucet Mantenimiento del Cartucho Cartridge Installation Cierre el suministro de agua antes de comenzar desenrosque el opresor del maneral retire el maneral y el chapetón Shut off water before you start unscrew the setscrew of the handle remove the handle and escutcheon 18 maneral handle opresor setscrew chapetón escutcheon cartucho cartridge tuerc...

Page 6: ...s on www helvex com mx Recomendaciones de Limpieza Cleaning Recommendations Posibles Causas y Soluciones Possible Causes and Solutions No se colocó el empaque The gasket is not placed Problema Problem Causas Causes Solucións Solutions Existe poco flujo de agua There is some water flow Aireador obstruido Clogged areator La presión de opreación no es la adecuada The operating pressure is not adequat...

Reviews: