FM
4
FC66003934 - Rev 13
/ All copying, even partial, of this manual is strictly forbidden.
UNITS’ PERFORMANCE TABLE
FM
22
32
42
min
med
max
min
med
max
min
med
max
Speed
1
2
3
1
2
3
1
2
3
Total cooling capacity
(1)(E)
kW
1,21
1,43
1,82
1,86
2,47
3,01
2,66
3,26
3,71
Sensible cooling capacity
(1)(E)
kW
1,00
1,20
1,53
1,35
1,81
2,22
1,94
2,40
2,74
FCEER class
C
B
B
Water flow
(2)
l/h
191
229
288
227
301
367
458
561
639
Water pressure drop
(2)(E)
kPa
12
19
29
16
28
39
28
40
50
Valve pressure drop
(3)
kPa
2
3
5
5
6
11
11
16
21
Heating capacity
(4)(E)
kW
1,38
1,76
2,23
2,07
2,65
3,25
3,12
3,86
4,06
FCCOP class
C
B
B
Water flow
(4)
l/h
250
303
384
289
369
453
537
665
699
Water pressure drop
(4)(E)
kPa
12
19
29
17
28
39
32
46
52
Rated air flow
m³/h
290
370
500
370
500
645
570
740
788
Power input
W
10
13
18
10
15
22
13
20
30
Total sound power level
(5)(E)
dB(A)
33
35
45
40
43
54
46
53
58
Water content - standard coil
dm³
0,08
0,12
0,19
Water connections (gas female)
“
1/2
Condensate discharge
mm
16
Height
mm
300
300
300
Depth
mm
228
228
228
Length
mm
876
876
876
Net weight
kg
12
13
14
(1) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015
(2) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)
(3) Inlet water temperature 50°C, water flow rate same as in cooling mode, air temperature 20°C
(4) Water temperature 45°C / 40°C, air temperature 20°C
(5) Sound power measured according to standards ISO 3741 and ISO 3742
(E) EUROVENT certified data
Power supply 230-1-50 or 220/-1-60 (V-ph-Hz)
È severamente vietata la riproduzione anche parziale di questo manuale.