all copying, even par tial, of this manual is strictly forbidden
FC66003632 - Rev 00
5
ESTRO BLDC
2 MODELS AND CONSTRUCTIvE COMpONENTS
Fp Ceiling mounted
> Cabinet composed of a steel
sheet panel (thickness 10/10
mm), side panels and air outlet
grille (swinging by 180°) built
from ABS.The side doors make it
possible to access the technical
compartments and the control
panel (accessory).
> Bearing structure built from thick galvanised steel sheet (thickness up
to 15/10 mm), insulated by means of Class 1 self-extinguishing panels.
The unit is supplied complete with a double condensate collection and
drainage system; in case of horizontal installation, condensate is collected
in a capacious drip tray.
> High efficiency heat exchanger made with copper piping and aluminium
fins blocked to pipings by mechanical expansion, provided with brass
manifolds and air vent valve. The heat exchanger usually comes with
water connections mounted on the left, but it can be turned by 180°.
> Permanent magnets electric synchronous motor (BLDC) mounted on
vibration damping supports, complete with sinusoidal inverter board.
> Double suction centrifugal fans, statically and dynamically balanced,
directly connected to the electrical motor, made with antistatic ABS, with
blades having an airfoil section and offset modules, or aluminium.
> Honey-comb polypropylene washable air filter, mounted on a galvanised
sheet frame protected by a net, easily removable for maintenance
operations. The filter is secured to the cabinet with ¼-turn screws.
FC vertical / horizontal recess
mounted
> Bearing structure built from
thick galvanised steel sheet
(thickness up to 15/10 mm),
insulated by means of Class 1
self-extinguishing panels. The
unit is supplied complete with
a double condensate collection
and drainage system; in case of
horizontal installation, condensate is collected in a capacious drip tray.
> High efficiency heat exchanger made with copper piping and aluminium
fins blocked to pipings by mechanical expansion, provided with brass
manifolds and vent valve. The heat exchanger usually comes with water
connections mounted on the left, but it can be turned by 180°.
> Permanent magnets electric synchronous motor (BLDC) mounted on
vibration damping supports, complete with sinusoidal inverter board.
> Double suction centrifugal fans, statically and dynamically balanced,
directly connected to the electrical motor, made with antistatic ABS, with
blades having an airfoil section and offset modules, or aluminium.
> Honey-comb polypropylene washable air filter, mounted on a galvanised
sheet frame protected by a net, easily removable for maintenance
operations.