10 ACCESSORIES

pH - painted rear covering panel for horizontal 
installation models FUI

The painted rear panel PH is supplied exclusively 
for ceiling mounted éstro FUI fan coils with 
apparent rear part in order to cover the technical 
compartments (plumbing and electrical). It is 
used to cover the technical compartments. The 
fan coils with rear panel can work in heating mode only.

GE+C - Aluminium air intake grille with 

subframe

The external air intake louver with anodised 
aluminium fixed fins, complete with anodised 
aluminium subframe is usually combined with 
external air intake louvers and is designed for 
wall mounting.

GEF+C - Aluminium air intake grille with 
subframe and filter

The air intake louvers with anodised aluminium 
fixed fins complete with washable acrylic fibre 
filter and galvanised sheet subframe, is usually 
combined with recess mounted fan coils.

GM+C - Anodised aluminium double-row 
finned air outlet grille, complete with 
subframe

Anodized aluminium air outlet grille with 2-row 
swinging fins complete with galvanized sheet 
steel subframe. It is usually combined with 
recessed mounted fan coils.

S - Manual external air intake louver

The manual external air intake louver is designed 
to allow frequent air renewals directly from the 
fan coil. The quantity of renewal air is filtered and 
heat treated by the fan coil and manually adjusted 
by means of the flap located inside.  This louver 
can be used on all éstro BLDC models except 
the floor mounted FU version. The installation of 
a pair of covering feet (ZL for FLI fan coils and 
ZA for FAI fan coils) is required, when the louver 
is mounted on fan coil units with cabinet (FLI, FAI and FPI ceiling mounted).

SM - Motor-driven external air intake louver

The motor driven external air intake louver is 
designed to allow frequent air renewals directly 
from the fan coil. The quantity of filtered and heat 
treated external air is proportionally controlled 
from 0 to 100% by means of a servomotor 
located inside.    
The SM - SM-C kit is complete with servomotor 
(protection rating IP54, 24 V supply voltage) and 230V - 24V transformer. The 
automatic closure and opening of the louver can be obtained by means of 
external auxiliary contacts (not supplied) as anti-freeze thermostats, timers, 
etc. by connecting in parallel several servomotors to a single opening-closing 
control.  The louver should be coupled to one of the following control panels 
(optional): CSB (installation on the unit) and CSD (wall recess mounted), 
permitting to close and open the louver from 0 to 100%. 
This louver can be used on all éstro BLDC models except the floor mounted 
FUI version. The installation of a pair of covering feet (ZL for FLI fan coils 
and ZA for FAI fan coils) is required, when the louver is mounted on fan coil 
units with cabinet (FLI, FAI and FPI ceiling mounted).

CSD - Recess mounted control for opening and 

closing the SM motor-driven regulating valve

Designed for wall recess mounting on the 
opposite side of the fan coil control panel, it 
controls the proportional opening and closing 
of the motor-driven regulating louver SM (from 
0 to 100%).

DF - Additional heat exchanger for 4-pipe 
systems (hot water circuit)

Additional heat exchanger made with copper 
piping and aluminium fins: it is suitable for 
4-pipe systems and is connected to the heating 
circuit.  
The heat exchanger comes complete with air 
vent valves on the system connection openings. 
The kit comes compete with locking bracket to 
avoid the manifold rotation during plumbing 
connection opereations. The performances of the heat exchanger mounted 
on the éstro BLDC fan coils are certified by Eurovent which guarantees the 
reliability of the data shown on this manual.

vK - ON-OFF 3-way motor driven valve, with 
hydraulic kit

The ON/OFF motor driven VK 3-way valve/4 
connections kit connected to the control 
panel for éstro fan coils, controls the room 
temperature by stopping the water flow through 
the heat exchanger. VK kit is available in various 
configurations for all models of éstro fan coils 
with standard (VK S) or additional DF (VK DF) 
heat exchanger, as shown in the table below:
The kit includes:
brass 3-way valve / 4 connections with built-in by-pass, maximum operating 
pressure 16 bar;
electrothermal actuator with the ON/OFF functions (total opening time 4 
minutes), 230 V power supply;
Hydraulic kit for installing the valve on the heat exchanger, complete with 2 
holders for balancing and regulating the fan coil unit.

Summary of Contents for ESTRO BLDC FLI

Page 1: ...TECHNICAL MANUAL GB ESTRO BLDC ESTRO BLDC FAN COILS BRUSHLESS TECHNOLOGY 1 5 kW 9 0 kW...

Page 2: ...ns 22 24 7 Wiring diagrams 25 8 VERSIONS WITH SEPARATE INVERTER 26 8 1 Inverter regulation procedure 26 8 2 Inverter board 27 8 3 Alarms 27 9 VERSIONS WITH INTEGRATED INVERTER 28 10 Accessories 29 31...

Page 3: ...pumps water circulation pumps etc Another analog output makes it possible to control the modulating valves Permanent magnets electric motor mounted on vibration damping couplings complete with windin...

Page 4: ...y a net easily removable for maintenance operations The filter is secured to the cabinet with turn screws FAI Wall mounting Cabinet composed of a thick steel sheet panel 10 10 mm side panels and air o...

Page 5: ...otor made with antistatic ABS with blades having an airfoil section and offset modules or aluminium Honey comb polypropylene washable air filter mounted on a galvanised sheet frame protected by a net...

Page 6: ...or horizontal installation fan coils with cabinet FUI Motor driven valves and drip trays VK S 3 way valve with ON OFF electrothermal motor and hydraulic kit for standard heat exchanger ALL VK DF 3 way...

Page 7: ...able Water flow l h 118 132 149 178 187 201 136 137 156 177 187 201 136 137 156 177 187 201 not available Pressure drop kPa 3 4 4 6 7 8 5 5 7 8 9 10 5 5 7 8 9 10 not available Water connections std in...

Page 8: ...10 11 12 Water connections std inches 1 2 1 2 1 2 1 2 DF inches not available 1 2 not available 1 2 Water content std dm3 1 33 1 4 1 8 1 4 DF dm3 not available 0 4 not available 0 4 ESTRO BLDC 1 2 9M...

Page 9: ...30 147 4 4 0 211 41 1450 1000 248 9 1280 930 219 7 1100 850 188 6 890 770 153 4 5 2 271 45 1780 1240 305 13 1570 1150 270 11 1350 1060 232 8 1110 960 190 6 6 4 344 51 2160 1500 370 19 1910 1400 327 15...

Page 10: ...3 1880 1560 322 3 1630 1460 281 2 4 2 470 43 3020 2160 519 6 2560 1970 439 5 2040 1770 351 3 1770 1660 304 3 5 5 605 49 3700 2720 635 9 3170 2510 545 7 2550 2260 438 5 2160 2150 371 4 7 3 785 56 4570...

Page 11: ...080 860 185 5 4 0 211 41 1660 1130 285 12 1500 1060 258 10 1330 990 228 8 1140 920 196 6 5 2 271 45 2050 1400 351 17 1850 1320 317 14 1640 1230 281 11 1410 1140 242 9 6 4 344 51 2480 1700 426 24 2240...

Page 12: ...386 4 1910 1670 329 3 4 2 470 43 3570 2490 613 9 3170 2320 544 7 2710 2140 466 5 2150 1920 370 4 5 5 605 49 4350 3120 747 12 3870 2920 664 10 3340 2710 574 8 2730 2480 469 5 7 3 785 56 5360 3890 919...

Page 13: ...0 456 15 6920 306 7 4M 3 7 196 33 1430 249 8 2260 197 5 2900 254 7 3930 174 4 4 0 211 41 1530 265 9 2400 210 5 3080 270 8 4180 185 4 5 2 271 45 1880 328 12 2960 259 8 3800 333 12 5140 227 6 6 4 344 51...

Page 14: ...2 9 3 4 389 39 3030 526 6 4790 418 3 6120 537 5 8370 369 3 4 2 470 43 3310 575 6 5190 454 4 6690 588 6 9060 400 3 5 5 605 49 4080 709 9 6400 559 6 8250 724 9 11120 491 4 7 3 785 56 4980 866 13 7790 68...

Page 15: ...0 434 14 6670 294 7 4M 3 7 196 33 1300 226 6 2120 185 4 2760 242 7 3790 167 3 4 0 211 41 1390 241 7 2260 197 5 2930 258 7 4030 178 4 5 2 271 45 1710 297 10 2780 243 7 3620 318 11 4960 219 5 6 4 344 51...

Page 16: ...11 9 3 4 389 39 2750 478 5 4490 393 3 5830 511 5 8050 356 2 4 2 470 43 3000 521 5 4870 426 4 6370 559 6 8720 385 3 5 5 605 49 3700 643 8 6010 525 5 7850 689 8 10710 473 4 7 3 785 56 4510 785 11 7320...

Page 17: ...860 150 7 1330 116 4 1780 156 7 2320 102 3 6 4 344 49 980 170 8 1510 132 5 2020 177 8 2620 115 4 7 0 380 52 1030 180 9 1590 139 6 2130 187 9 2760 122 4 8 3 450 55 1110 193 11 1710 149 6 2290 201 10 2...

Page 18: ...4 7 4790 420 11 6240 275 5 6 6 706 53 2460 427 13 3790 331 8 5050 443 12 6580 290 6 8 0 855 57 2680 467 15 4130 361 9 5520 484 14 7170 317 7 8 8 938 60 2800 487 16 4310 377 10 5770 506 16 7480 330 7 9...

Page 19: ...44 770 134 6 1240 108 4 1690 149 6 2230 98 3 6 4 344 49 880 153 7 1400 123 4 1920 168 8 2510 111 3 7 0 380 52 930 161 8 1480 129 5 2020 177 8 2650 117 4 8 3 450 55 1000 174 9 1590 139 6 2180 191 9 28...

Page 20: ...94 6 4550 399 10 6000 265 5 6 6 706 53 2210 385 11 3540 310 7 4800 421 11 6320 279 5 8 0 855 57 2420 420 12 3860 338 8 5250 460 13 6890 304 6 8 8 938 60 2520 438 13 4030 352 9 5480 480 14 7190 317 7 9...

Page 21: ...40 5 9 640 45 00 51 20 48 50 42 50 37 90 28 50 18 40 49 7 4 798 51 00 57 20 54 50 48 50 43 90 34 50 24 40 55 8 0 855 53 00 59 20 56 50 50 50 45 90 36 50 26 40 57 8 8 938 55 00 61 20 58 50 52 50 47 90...

Page 22: ...4 226 708 51 458 163 263 149 198 187 335 99 486 7 9 1194 226 918 51 458 163 263 149 198 187 335 99 486 95 1194 251 918 48 497 185 259 155 220 195 348 120 478 11 1404 251 1128 48 497 185 259 155 220 19...

Page 23: ...08 198 5 6 984 226 708 51 458 163 263 1187 335 99 486 208 198 7 9 1194 226 918 51 458 163 263 1187 335 99 486 208 198 95 1194 251 918 48 497 185 259 195 348 120 478 234 208 11 1404 251 1128 48 497 185...

Page 24: ...DF 5 Drain outlet 6 Air outlet 7 Air intake FCI A B C D E F G H L M N P Q R S T U V Y 1 4 584 224 498 51 458 163 263 149 198 187 335 99 189 486 208 198 436 464 61 5 6 794 224 708 51 458 163 263 149 1...

Page 25: ...sensor SU Humidity sensor DI1 Digital 1 input DI2 Digital 2 input CI12 Digital input common For each fan coil a switch IL should be mounted on the power supply with opening contacts at a distance of a...

Page 26: ...p switched as shown in the following figure No MAX speed DIP 1 DIP 2 DIP 3 DIP 4 1 1550 rpm OFF OFF OFF 2 1450 rpm ON OFF OFF 3 1350 rpm OFF ON OFF 4 1250 rpm ON ON OFF 5 1150 rpm OFF OFF ON 6 1050 rp...

Page 27: ...all copying even par tial of this manual is strictly forbidden FC66003632 Rev 00 27 ESTRO BLDC 8 VERSIONS WITH SEPARATE INVERTER 8 2 INVERTER BOARD 8 3 ALARMS...

Page 28: ...nd 1 Strip Molex Micro Fit 3 0 04365 00400 to be used with 04364 50400 1 1 10V 1 2 Tachometer outlet 1 3 0 10V lin signal PWM 1 4 GND 2 Lumberg 3642 03 K01connector to be used with 3626 03 K01 2 1 PE...

Page 29: ...signedfortheinstallation on stro FLI models are supplied in pairs and comprisesupportsforfasteningtothebaseunit andoutercoveringsforfasteningtothecabinet They are used to conceal the plumbing pipes le...

Page 30: ...24V transformer The automatic closure and opening of the louver can be obtained by means of external auxiliary contacts not supplied as anti freeze thermostats timers etc by connecting in parallel sev...

Page 31: ...p to 8 l h of water RA RM Inlet and outlet connectors These accessories are designed for stro BLDC FCI FFI fan coils and are used for room ducts when the basic unit stro BLDC FCI is placed within fals...

Page 32: ...e user to set the functions while ensuring an accurate reading of the ambient temperature if provided You should avoid positions directly exposed to sunlight positions exposed to direct currents of wa...

Reviews: