background image

14 

 

 

 

Sliding System 

No. 

Part Name 

Part No. 

Qty. 

Cooper bush 

1200075 

Sliding Lower Platen Base 

1200426 

Supporting Block 

1200052 

Bearing block 

1200648 

Plated bar fixed board 

1200044 

Plated bar 

1701037 

O shape washer 

1200309 

 

 

 

 

 

 

 

Summary of Contents for GS-105HS

Page 1: ...orrect assembly or repair could increase the risk of fire electric shock or injury to persons when the equipment is used 7 This appliance is not intended to be used by persons including children with...

Page 2: ...mble the Control Box 6 Connecting the System 7 Ramspin system Auto Manual switch 7 Turning the System On 8 Adjusting the Temperature 8 Adjusting the Time 8 Adjusting the Pressure 9 Printing and Pressi...

Page 3: ...ower Platen Yes Power 110volt 1800W 16 4Amps Temperature Range Max 430 221 Heating Up Time 180 20 minutes Time Range 0 999S Platen Exchange System Ramlock quick change system Optional Lower Platens So...

Page 4: ...4...

Page 5: ...5 Control Panel Guide Operation Instructions...

Page 6: ...machine in the right position figure 1 1 1 2 Fasten the control box onto the machine with 4 screws tightly figure 1 2 1 3 Connect 5 phase aviation plug and 2 phase aviation plugs then fasten tightly f...

Page 7: ...ces especially more than one heat seal machine plugged in should not be used NOTE If the supply cord is damaged be sure to contact the manufacturer its service agent or a similar qualified person for...

Page 8: ...e 4 ADJUST THE TEMPERATURE 4 1 Press SET button Set Temp lights located in the display will illuminate figure 4 1 4 2 Next press the UP and DOWN Arrow to increase or decrease the figure to set the Tem...

Page 9: ...2 Next press UP and DOWN Arrow to increase or decrease the figure to set the Time The time setting range is from 0 to 999S 6 1 Once you have adjusted the time press SET button again Counter lights lo...

Page 10: ...wise to decrease the Pressure The readout will display the Pressure when locked down in the print position 7 3 A visual Pressure Readout is located on the lower right side of the LCD Display When the...

Page 11: ...nds Calibrate lights located in the display will illuminate indicating you are in the adjust temperature calibration mode fig 10 1 9 1 Press the UP Arrow and SET button together and hold for 3 seconds...

Page 12: ...446 1 3 Circuit breaker 18A 1800349 1 4 On off switch 1800346 1 5 Emergency stop button 1200579 1 6 socket 1800344 1 7 Triac 1800586 1 10 Cooing sheet 1300672 1 11 Terminal Block 1800345 1 12 Circuit...

Page 13: ...0155 1 36 Screw M8 16 1901071 1 37 Adjustment spindle base 1800142 1 39 Adjustment spindle 1800087 1 40 Thermocouple 1800281 1 42 Balance screw 1901074 1 43 Thermostat 1800133 1 44 Lower platen 180038...

Page 14: ...art Name Part No Qty 1 Cooper bush 1200075 4 3 Sliding Lower Platen Base 1200426 1 4 Supporting Block 1200052 1 4 Bearing block 1200648 4 5 Plated bar fixed board 1200044 2 6 Plated bar 1701037 2 7 O...

Page 15: ...amlock locking screw 1900959 1 5 Ramlock handle 1200956 1 6 Ramlock locking set female 1200957 1 Optional Platens Sold Separately Part Name SKU Size LTPPLATENSETRAM 0404 4in x 4in LTPPLATENSETRAM 0610...

Page 16: ...16 Electrical Schematic...