Galaxy Unlimited, LLC Remote Control Box Warranty 

 

This warranty is for the electrical components of the Remote Control Box which begins on the day of purchase from 
Galaxy Unlimited, LLC for a period of 1 year thereafter. During this period, Galaxy Unlimited, LLC will replace electrical 
components, without charge, for the components of the Remote Control Box, or any part or piece thereof, which 
exhibits a manufacturing defect or defect in craftsmanship. Defect is determined at the absolute and sole discretion 
of Galaxy Unlimited, LLC. 

 

To submit an acceptable claim under this limited warranty, the Original Purchaser must provide the following 
information in writing to: 

 

Galaxy Unlimited, LLC 6470 State Highway 198 
Mabank, TX 75156 

 

 

Full Name and Address 

 

Serial Number of Unit 

 

Clear and specific description of the defect 

 

Ship malfunctioning Remote Control Box to above address for confirmation/evaluation at the expense of 
the customer. 

 

Must register Control Box online. 

 

This limited warranty is valid only when such products are used under normal conditions of recommended use. This 
limited warranty does not cover replacement or repair of any part there of damaged by acts of God, abuse, accident, 
misuse,  neglect,  alteration,  repair,  disaster,  overloading,  negligence,  unauthorized  use,  improper  installation, 
improper  testing,  improper  product  selection,  failure  to  follow  maintenance  recommendations, failure to follow 
instructions or warnings, or any other case beyond the control of Galaxy Unlimited, LLC. 

 

All  warranties  implied  by  law,  including  implied  warranties  of  merchantability  and  fitness  for  a  purpose,  are 
disclaimed or, if a disclaimer is not permitted by applicable state law, are expressly limited to the durations of the 
coverage period set forth above. 

 

Summary of Contents for 1M2S

Page 1: ...1M2S Control Box Wiring Programming Guide...

Page 2: ...ote s Figure 3 Control Board Figure 8 Magnetic Limit Switch Wired Portion Figure 7 Magnetic Limit Switch Non Wired Portion Figure 6 Magnetic Limit Switch Mounting Bracket Figure 4 Call Send Box Figure...

Page 3: ...nctions The Gel Pad is the primary control center for your lift The Gel Pad can turn your unit off and on send the unit to its levels or stop the travel in any direction The remotes are programmed fro...

Page 4: ...ess the up button on each remote once you will see a corresponding flash from the learn LED 4 Give the learn mode 10 seconds to expire you will see a rapid flash from the learn LED 5 Now test the remo...

Page 5: ......

Page 6: ...240 Volt standard Lift Wiring...

Page 7: ...e indicated in the Control box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 Orange T4 Red T5 Join T2 T3 T8 Inside Control...

Page 8: ...120 Volt Standard Lift Wiring...

Page 9: ...rol box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 T3 Orange T2 T4 Red T5 White T8 Inside Control Box Motor Wiring Oran...

Page 10: ...or 240V or 120V Overlimit Set Up 1 Connect the black wire from the Overlimit cable to the black wire coming from the 9 Pin Molex connecter 2 Connect the white wire from the Overlimit cable to the blac...

Page 11: ......

Page 12: ...porarily mount the Non wired Component of the Magnetic Limit Switch on the outside of one of the external backbones of the cargo lift Either of the two backbones is acceptable but note that the Wired...

Page 13: ...re 15 5 For reference the figure 16 below show the Control Board CB outside the control box Figure 15 shows the CB installed inside the control box There are 3 wires red green black coming from the mi...

Page 14: ...Limits CB...

Page 15: ...tch is not used 10 Use wire nuts to secure the connections 11 Carefully replace the Gel Pad on the control box with the four screws that secure the pad 12 Using the up and down buttons on the control...

Page 16: ...Additional Equipment Setup Section Not Standard Call Send...

Page 17: ...the control box while attaching the wires 3 Find the blue screw terminals located near the Gel Pad connector as shown in figure 18 below 4 Connect the wires from the call send station as shown in the...

Page 18: ...ot Standard Pan switch 1 Connect the black wire from the Pan Switch to the green limit wire coming off the control board 2 Connect the white wire from the Pan Switch to the red wire coming off the bot...

Page 19: ...el cable through the gland and start making the necessary connections at the bottom of the basket a Black wire from travel cable to the White wire from Rocker Switch 1 See Diagram Below then connect t...

Page 20: ......

Page 21: ...ar and specific description of the defect Ship malfunctioning Remote Control Box to above address for confirmation evaluation at the expense of the customer Must register Control Box online This limit...