Magnetic Limit Switch Set Up Continued 

6.

 

The Wired component of the Magnetic Limit Switch contains three colored wires (white, red, black). Note that 
the black wire will not be used in this installation. 
 

 

7.

 

Run the ends of the wire for Upper Magnetic Limit Switch, and the Lower Magnetic Limit Switch through the 
cable glands in the bottom of the control box.  

8.

 

To connect the Top Magnetic limit switch, connect the black limit wire from the CB to the white wire for the Top 
Magnetic limit switch. Connect the red limit wire from the CB to red wire from the Top Mag.  
Note the black wire for the magnetic limit switch is not used. 

9.

 

To Connect the Bottom Magnetic Limit Switch, connect the black limit wire from the CB to the white wire for the 
Bottom Magnetic Limit Switch. Connect the green limit wire from the CB to the red wire for the Bottom 
Magnetic Limit Switch.  
Note the black wire for the Magnetic Limit Switch is not used. 

10.

 

Use wire nuts to secure the connections. 

11.

 

Carefully replace the Gel Pad on the control box with the four screws that secure the pad. 

12.

 

Using the up and down buttons on the control pad, move the lift to the top and bottom positions, testing the 
stopping points. Utilizing the two-sided tape, move either one of the two Components of the upper or lower 
magnetic limit switch as needed to achieve the desired stopping point. 

13.

 

When the lift is stopping in the desired positions, mark the location for drilling the holes for the attaching 
screws. There are two holes required for the Non-Wired Component. Use a 

1/8”

 drill bit and two self-tapping 

screws or two through bolts and nuts as appropriate. 

14.

 

The wired component will need on hole in the middle of the vertical slot. This will allow for the minor 
adjustments up or down to the stopping position in the future. A second hole can be drilled in the two 
horizontal slots to firmly secure the mounting plate. Use a 

1/8”

 drill bit and two self-tapping screws or two 

through bolts and nuts as appropriate. 

 

 

 

Figure 17. Magnetic Limit Switch wires 

Summary of Contents for 1M2S

Page 1: ...1M2S Control Box Wiring Programming Guide...

Page 2: ...ote s Figure 3 Control Board Figure 8 Magnetic Limit Switch Wired Portion Figure 7 Magnetic Limit Switch Non Wired Portion Figure 6 Magnetic Limit Switch Mounting Bracket Figure 4 Call Send Box Figure...

Page 3: ...nctions The Gel Pad is the primary control center for your lift The Gel Pad can turn your unit off and on send the unit to its levels or stop the travel in any direction The remotes are programmed fro...

Page 4: ...ess the up button on each remote once you will see a corresponding flash from the learn LED 4 Give the learn mode 10 seconds to expire you will see a rapid flash from the learn LED 5 Now test the remo...

Page 5: ......

Page 6: ...240 Volt standard Lift Wiring...

Page 7: ...e indicated in the Control box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 Orange T4 Red T5 Join T2 T3 T8 Inside Control...

Page 8: ...120 Volt Standard Lift Wiring...

Page 9: ...rol box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 T3 Orange T2 T4 Red T5 White T8 Inside Control Box Motor Wiring Oran...

Page 10: ...or 240V or 120V Overlimit Set Up 1 Connect the black wire from the Overlimit cable to the black wire coming from the 9 Pin Molex connecter 2 Connect the white wire from the Overlimit cable to the blac...

Page 11: ......

Page 12: ...porarily mount the Non wired Component of the Magnetic Limit Switch on the outside of one of the external backbones of the cargo lift Either of the two backbones is acceptable but note that the Wired...

Page 13: ...re 15 5 For reference the figure 16 below show the Control Board CB outside the control box Figure 15 shows the CB installed inside the control box There are 3 wires red green black coming from the mi...

Page 14: ...Limits CB...

Page 15: ...tch is not used 10 Use wire nuts to secure the connections 11 Carefully replace the Gel Pad on the control box with the four screws that secure the pad 12 Using the up and down buttons on the control...

Page 16: ...Additional Equipment Setup Section Not Standard Call Send...

Page 17: ...the control box while attaching the wires 3 Find the blue screw terminals located near the Gel Pad connector as shown in figure 18 below 4 Connect the wires from the call send station as shown in the...

Page 18: ...ot Standard Pan switch 1 Connect the black wire from the Pan Switch to the green limit wire coming off the control board 2 Connect the white wire from the Pan Switch to the red wire coming off the bot...

Page 19: ...el cable through the gland and start making the necessary connections at the bottom of the basket a Black wire from travel cable to the White wire from Rocker Switch 1 See Diagram Below then connect t...

Page 20: ......

Page 21: ...ar and specific description of the defect Ship malfunctioning Remote Control Box to above address for confirmation evaluation at the expense of the customer Must register Control Box online This limit...

Reviews: