29
Attack Time page
- from this page, it is possible to set the Attack Time parameters of the RMS
Compressor.
Upon pushing “ENTER”, the RMS Compressor’s Attack Time editing page can be entered and using the
“PM3” encoder, the “Attack Time” parameter can be set.
“Attack Time”
- the selectable range of the RMS Compressor’s Attack Time is from 5ms to 200ms, in
steps of 1ms from 5ms to 20ms, then in steps of 5ms from 20ms to 30ms, then in steps of 10ms from 30ms
to 100ms, and then in steps of 20ms, from 100ms to 200ms.
Release Time page
- from this page, it is possible to set the Release Time parameters of the RMS
Compressor.
Upon pushing “ENTER”, the RMS Compressor’s Release Time editing page can be entered, and using the
“PM3” encoder, the “Release Time” parameter can be set.
“Release Time”
- the selectable range of the RMS Compressor’s Release Time is from 0.1s to 3s in steps
of 0.1s.
Threshold page
- from this page, it is possible to set the Threshold parameters of the RMS Compressor.
Upon pushing “ENTER”, the RMS Compressor’s Threshold editing page can be entered and using the
“
PM3” encoder, the “Threshold” parameter can be set.
“Threshold”
- the selectable range of the RMS Compressor’s Threshold is from +20dBu (OFF) to -5dBu in
steps of 0.2dBu.
Ratio page
- from this page, it is possible to set the Ratio parameters of the RMS Compressor.
Upon pushing “ENTER”, the RMS Compressor’s Ratio editing page can be entered and using the PM3”
“
encoder, the “Ratio parameter can be set.
”
“Ratio”
- the selectable range of the RMS Compressor’s Ratio is from 1:1 (Off) up to 32:1 (Lim) in steps of
0.2.
OutputA Left Cmp1
-> Ratio [I/O] = 4:1
OutputA Left Cmp1
-> Threshold = 50ms
OutputA Left Cmp1
-> Release Time = 250ms
OutputA Left Cmp1
-> Attack Time = 50ms