![Galanz XQG80-Q812DE After-Sales Service Manual Download Page 30](http://html1.mh-extra.com/html/galanz/xqg80-q812de/xqg80-q812de_after-sales-service-manual_3245530030.webp)
XYJGT80QFSDE-001
29
4
、电脑板故
障
4.Main
board is
damaged
4
、更换电脑板
4. Change the
main board
E06
水加热管故
障
There is a
heating tube
fault
1
、加热超时(连
续加热设定时间,
检测温度
NTC
数
值变化小于
2
)
1.Heating timeout
(continuous
heating for setting
time, the change
of NTC value of
detection
temperature is
less than 2)
1
、加热管线
束端子松动
或线束故障
1.The
connection
between the
heating tube
and wire is
not secure
or wire is
damaged
1
、检查线束端子
插接是否牢固或
更换线束
1. Check the
connection and
ensure it is
secure or change
wire
跳过加热阶
段,程序结
束后报警
Skip the
heating
phase,
alarm after
the end of
the
program
关闭
电源
Turn
off the
power
2
、加热管故
障
2. The
heating
tubeis
damaged
2
、更换加热管
2. Change the
heating tube
2
、水加热温度传
感器超过
90
℃但
没有报
E7
错误
2.Water heating
temperature
sensor exceeds
90
℃
, but E7
error is not
reported
3
、电脑板故
障
3. Main
board is
damaged
3
、更换电脑板
3.Change the
main board
闭合门锁,
关闭所有负
载
(
不排水
)
Close the
door lock
and close
all loads
(undrained
)