![Galanz XQG80-Q812DE After-Sales Service Manual Download Page 25](http://html1.mh-extra.com/html/galanz/xqg80-q812de/xqg80-q812de_after-sales-service-manual_3245530025.webp)
XYJGT80QFSDE-001
24
7.
异常报警
/
异常指示
Abnormality Alarms / Abnormality Indications
注:请先仔细检查故障原因再更换元器件。
Note: Please check the cause of the failure carefully before replacing the components.
报警
代码
故障描述
故障条件
可能故
障原因
处理方法
机器状态
复位
方式
Alarm
code
Fault
description
Fault conditions
Possible
cause of
failure
processing
method
Machine
status
Reset
mode
E01
进水超时
The water of
machine fills
overtime
进水超过设定时
间尚未到达设定
水位
the water level
has not reached
the set level for
more than setting
time
水龙头未打
开或水流太
慢
1. Water tap
is not open
1
、检查水龙头开
启否及水流大小
1.Open the water
tap
暂停
Pause
启停
键复
位
start
stop
key
reset
2
、排水管未
挂起
2. Drain
hose is put
down
2
、挂起排水管
2.Hook up the
hose
3
、水位开关
或集气管漏
气
3. Leakage
of water
level switch
or gas
collecting
pipe
3
、检查水位开关
和集气管装配,或
更换
3. Check the
assembly of
water level
switch and gas
collecting pipe,
or change it
关闭
电源
Turn
off the
power
4
、水位开关
端 子 未 插 好
或线束故障
4.The
connection
between the
water
sensor and
wire is not
secure or
wire is
damaged
4
、检查线束端子
插 接 是 否 牢 固 或
更换线束
4. Check the
connection and
ensure it is
secure or change
wire