3.2.1. REGULATION LEVELS.
The traditional current level can be determined in table 4 (as per standard EN 60974-1) for each
regulation point of the welding voltage of the equipment. The traditional level corresponds to the appropriate
current values for MG welding with pure CO
2
. We have added the approximate current level values for MAG
welding with gas mixture (75% CO
2
+ 25% Ar).
Table 4.
Traditional regulation levels (CO
2
) and gas mixture.
GALA MIG 6007
SCALE
Reg.
NO-
LOAD
TRADITIONAL
(CO
2
)
GAS MIXTURE
U
2o
(V)
U
2
(A)
I
2
(A)
U
2
(A)
I
2
(A)
1
17,0
16,1
40
71
15,5
2
17,4
16,4
48
77
15,9
3
17,7
16,7
53
82
16,2
4
18,1
17,0
59
88
16,4
5
18,5
17,2
64
93
16,7
6
18,9
17,5
69
98
17,1
7
19,2
17,7
75
103
17,2
8
19,6
18,0
79
108
17,5
9
19,9
18,2
84
113
17,9
I
10
20,2
18,4
89
117
17,9
1
20,6
18,7
95
123
18,2
2
21,2
19,1
103
131
18,5
3
21,8
19,6
111
140
18,9
4
22,3
20,0
119
148
19,4
5
22,9
20,4
127
156
19,7
6
23,4
20,7
135
164
20,1
7
24,0
21,1
143
171
20,6
8
24,5
21,5
150
179
20,9
9
25,0
21,9
157
186
21,3
II
10
25,5
22,2
164
193
21,6
1
26,2
22,7
174
203
22,1
2
27,1
23,4
187
216
22,5
3
28,0
24,0
200
229
22,9
4
28,9
24,7
213
242
24,1
5
29,9
25,3
227
255
24,5
6
30,8
26,0
240
268
24,8
7
31,7
26,7
253
282
26,1
8
32,6
27,3
266
294
26,4
9
33,5
27,9
278
307
26,8
III
10
34,3
28,5
290
319
28,0
1
35,6
29,4
308
336
28,8
2
37,3
30,6
333
361
29,2
3
39,0
31,9
357
386
29,6
4
40,7
33,1
382
410
32,5
5
42,6
34,4
409
437
32,9
6
44,5
35,8
435
464
33,3
7
46,3
37,1
462
490
36,5
8
48,2
38,4
490
517
36,9
9
50,1
39,8
520
544
37,3
IV
10
52,0
41,1
550
570
40,6