GAGGIA CADORNA 03 OPERATING LOGIC
3/6
When the coffee grinder is working, the software monitors the current consumption. If the current value is
very low, the machine concludes that coffee is missing; if the current value is very high, the machine concludes
that the coffee grinder is blocked; instead, if the current value is in the middle, the machine concludes that all
is ok and it goes on to do the product.
Because the current consumption of grinder changes depending on the situations (motor new or old, cold or
hot, etc., coffee blends), these current thresholds are not static, but dynamic.
1) When the system get the stability (i.e. the system got the current target) the coffee doses should be:
A1
A2/3
A4/5
7,5 9,0 10 ±1,5 grams
with medium grinding (500±60μm) and using coffee of test.
2) the 3 grinding times are always:
T
1
<T
2
<T
3
beside, every grinding time is, respectively:
4,0s
≤
T
3
≤
10s (10000ms)
3,5s
≤
T
2
≤
9s (9000ms)
3,0s
≤
T
1
≤
8,1s (8100ms)
3.5.
Coffee lack detection and coffee grinder blocked
DOSE ADJUSTMENT
5 levels
Grinder
Time
Min
Grinder
Time
Max
Grinder
Time
Curret target
Aroma
of the
grinded
product
Aroma1
Very Light
T
1
3s
8,1s
I
0 +
55mA
Aroma2
Light
T
2
3,5s
9s
I
0 +
100mA
Aroma3
Med
Aroma4
Strong
T
3
4s
10s
I
0 +
200mA
Aroma5
Very Strong
Summary of Contents for SUP 049
Page 4: ...GAGGIA CADORNA CHAPTER 1 INTRODUCTION ...
Page 7: ...GAGGIA CADORNA 01 INTRODUCTION 3 6 1 5 Electrical diagram ...
Page 11: ...GAGGIA CADORNA CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 16: ...GAGGIA CADORNA CHAPTER 3 OPERATING LOGIC ...
Page 23: ...GAGGIA CADORNA CHAPTER 4 TEST MODE AND STEAM OUT ...
Page 29: ...GAGGIA CADORNA CHAPTER 5 ESPRESSO PHILIPS SERVICE CENTER ...
Page 31: ...GAGGIA CADORNA CHAPTER 6 MACHINE REPAIR FLOW ...