GAGGIA CADORNA 04 TEST MODE & STEAM OUT
3/5
This page allow to test the functionality of Brew Unit and the microswitchs:
This page allow to test the functionality of hydraulic circuit:
The meaning of the sectors are the following:
• Work (my favorite bottom): when pressed move the brew unit to WORK
• Home (home bottom): when pressed move the brew unit to HOME
Info:
• mA: indicates the maximum current (in mA) absorbed by the brew unit in motion;
• H/W: Becomes active when the Brew Unit reach HOME or WORK position;
• Pres: Becomes active if the Brew Unit is present in machine;
• DDr: Becomes active if the Dump box is present in machine;
• Door: Becomes active if the Service Door is closed;
• Caraf 1: Becomes active if the water spout is present;
• Caraf 2: Becomes active if the Carafe is present.
The meaning of the sectors are the following:
• Command:
• Boiler (Setting bottom): when pressed activate/deactivate the boiler if the temperature is less than 90°C
• Pump (my favorite bottom): when pressed activate/deactivate the pump
• Ev S (home bottom): when pressed activate/deactivate the Steam/Water electrovalve (24V Dc)
Page 3: Brew Unit
Page 4: Hydraulic Circuit
CADORNA TEST MODE
user guide
nomeFile
Cadorna - Test mode
v0.0_ENG.doc
1.0
F.Bolognesi
04/06/2019
Page | 4
revNum
Redatto
SaveDate
Pagina/pagine
2.3 Brew Unit
This page allow to test the functionality of Brew Unit and the microswitchs:
e
g
a
p
t
x
e
N
Previous page
Exit
The meaning of the sectors are the following:
•
Work (my favorite bottom): when pressed move the brew unit to WORK
•
Home (home bottom): when pressed move the brew unit to HOME
Info:
•
mA: indicates the maximum current (in mA) absorbed by the brew unit in motion;
•
H/W: Becomes active when the Brew Unit reach HOME or WORK position;
•
Pres: Becomes active if the Brew Unit is present in machine;
•
DDr: Becomes active if the Dump box is present in machine;
•
Door: Becomes active if the Service Door is closed;
•
Caraf 1: Becomes active if the water spout is present;
C
M
Y
CM
MY
CY
CMY
K
3.pdf 1 05/07/2019 14:05:08
CADORNA TEST MODE
user guide
nomeFile
Cadorna - Test mode
v0.0_ENG.doc
1.0
F.Bolognesi
04/06/2019
Page | 5
revNum
Redatto
SaveDate
Pagina/pagine
2.4 Hydraulic Circuit
This page allow to test the functionality of hydraulic circuit:
Previous page Next page
Exit
The meaning of the sectors are the following:
•
Command:
•
Boiler (Setting bottom): when pressed activate/deactivate the boiler if the temperature is less than 90°C
•
Pump (my favorite bottom): when pressed activate/deactivate the pump
•
Ev S (home bottom): when pressed activate/deactivate the Steam/Water electrovalve (24V Dc)
Info:
•
p/s: indicate the current number of water flow expressed in pulses/sec. When is activated the pump
and one electrovalve the value measured must be equal to or greater than 10 p/s.
•
Tank: Becomes active when the water into tank reach sensor level
•
Frequency: indicate the frequency of mains voltage supply
•
Boiler Temperature: indicate the boiler temperature in °C
Summary of Contents for SUP 049
Page 4: ...GAGGIA CADORNA CHAPTER 1 INTRODUCTION ...
Page 7: ...GAGGIA CADORNA 01 INTRODUCTION 3 6 1 5 Electrical diagram ...
Page 11: ...GAGGIA CADORNA CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 16: ...GAGGIA CADORNA CHAPTER 3 OPERATING LOGIC ...
Page 23: ...GAGGIA CADORNA CHAPTER 4 TEST MODE AND STEAM OUT ...
Page 29: ...GAGGIA CADORNA CHAPTER 5 ESPRESSO PHILIPS SERVICE CENTER ...
Page 31: ...GAGGIA CADORNA CHAPTER 6 MACHINE REPAIR FLOW ...