Ideas with Passion
Level M4
At this level you can check water heater, relative ntc sensor and cup warmer function.
- When you press the steam key, the ambient temperature (tt.t) is shown on the second line of the display in degrees centi-
grade.
- When you press the water key, the state of the ntc sensor (open or short), on the water heater
(open or short), or the water heater temperature in degrees centigrade are shown on the second line of the display.
- Pressing the aroma key switches on the water heater (pressing the water key shows the rising temperature) and the string
Heater ON appears on the second line of the display.
- When you press the menu key, the cup warmer is switched on and the string
Cup Heater
(Ring Plus only) appears on the second line of the display.
Steamout
Open the knob in the water/steam position to prepare for steamout (draining water heater). Press the coffee key to start, the
water heater will be brought to 120°, at which time the machine emits a sequence of beeps.
WARNING: At the end of this procedure, the machine will automatically switch to English.
Level M5 (Cup lift position) on Ring Plus only.
At this level, you can check cup-lift function.
- Press the aroma key to move the cup-lift down to its lowermost position.
- Press the menu key to raise the cup-lift to its uppermost position.
Level M6 (LCD contrast)
You can change display contrast at this level.
- Press the coffee key to edit display contrast (the percentage value starts blinking).
- You can use the touch-ring to change this value: turn clockwise to increase it, and anticlockwise to decrease it.
- Press the coffee key again to save the value selected.
Level M7 (LCD backlight)
You can change display brightness at this level.
- Press the coffee key to change display brightness
(the percentage value starts blinking).
- You can use the touch-ring to change this value: turn clockwise to increase it, and anticlockwise to decrease it.
- Press the coffee key again to save the value selected.
Level M9
- Exit.
Press the coffee key to exit test mode and fully restart the appliance.
Level M8 (Self-test)
The machine automatically tests its main functions in the self-test.
The brew group must be present and the doors
closed.
On completion of this procedure (which lasts approx. 10 seconds), the outcome will appear on the display.
Pass!! and 2 consecutive beeps if it was successful.
If an error was encountered, 10 beeps will be emitted and a message appears on the display.
6/17
TALEA Section 05
REV00 - August 06
Summary of Contents for PLATINUM EVENT
Page 1: ...Emissione Luglio 2007 REV 00 TECHNICAL SERVICE MANUAL ...
Page 3: ...SECTION 1 INTRODUCTION REV 00 TALEA Section 01 REV00 August 06 ...
Page 6: ...EVENT S B S Rapid Steam TALEA ODEA Cap 01 REV00 Luglio 07 3 3 ...
Page 7: ...SECTION 2 TECHNICAL DATA REV 00 TALEA Section 02 REV00 August 06 ...
Page 10: ...Ideas with Passion SECTION 3 BRIEF INSTRUCTIONS REV 00 TALEA Section 03 REV00 August 06 ...
Page 14: ...Ideas with Passion SECTION 4 DIAGRAMS REV 00 TALEA Section 04 REV00 August 06 ...
Page 37: ...SECTION 6 OPERATING LOGIC REV 00 TALEA Section 06 REV00 August 06 ...
Page 58: ...Ideas with Passion SECTION 8 SERVICE SCHEDULE REV 00 TALEA Section 08 REV00 August 06 ...