61
English
NB.
The regenerating operations are applicable only
if the water softener is the same type as indicated in
the figures.
Proceed as indicated in the instructions attached to
the water softener if the water softener in question is
a different type.
14 WATER SOFTENER
REGENERATION
A WATER INLET
B WATER OUTPUT
C INLET TAP LEVER
D OUTLET VALVE LEVER
E DEPRESSION PIPE
F REGENERATION PIPE
G COVER KNOB
IMPORTANT:
Regenerate the water softener at the
expiry dates foreseen and indicated below:
- Position an empty container with a capacity of approxi-
mately 2 litres under pipe E
- Move levers C and D from left to right as indicated in fig.
8.2, remove the cover by unscrewing knob G, introduce
1.5 kg of sodium chloride (large grade kitchen salt) into
the 8 litres type water softener and 2 kg into the 12 litres
type water softener).
- Replace the cover and return lever C from right and left,
as indicated in fig. 8.3, allow the salt water to discharge
from pipe F until the water is fresh.
- Return lever D from right to left, as indicated in fig.
8.4.
HARDNESS °F
8 LITRE PURIFIER
12 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l.
regeneration after 1600 l
From 21 to 30
regeneration after 850 l.
regeneration after 1250 l.
From 31 to 40
regeneration after 650 l.
regeneration after 950 l.
From 41 to 60
regeneration after 450 l.