25
Fault, what to do?
Fault table
Fault
Cause
Remedial action
“Check water supply”
display
@
lights up.
Supply hose kinked.
Install supply hose without kinks.
Tap turned off.
Turn on the tap.
Tap jammed or calcified.
Turn on the tap.
Flow rate must be min. 10 l/min. when water
supply is open.
Filter in the water supply blocked.
Switch off the appliance and pull out
the mains plug. Turn off the tap. Unscrew
water connection.
Clean filter in the supply hose. Screw water
connection on again. Check for leaks. Recon-
nect power supply. Switch on the appliance.
Error code
“
:
ƒƒ
is lit.
Filters
1Z
are soiled or blocked.
Clean filters.
(See Cleaning and maintenance)
Error code
“
:
ƒ…
is lit.
Waste water hose is blocked or kinked. Install hose without kinks, remove any residue.
Siphon connection still sealed.
Check connection to siphon and open if
required.
Cover on the waste water pump loose.
Lock cover correctly.
(See Waste water pump)
Error code
“
:
Ġ
is lit.
Waste water pump blocked or cover
on the waste water pump is not locked
in position.
Clean pump and lock cover correctly. (See
Waste water pump)
Error code
“
:
ƒˆ
is lit.
Mains voltage too low.
Not an appliance fault, have the mains voltage
and electrical installation checked.
A different error code is indicated
on the digital display.
(
“
:
‹‚
to
“
:
„‹
)
A technical fault has probably
occurred.
Switch off appliances with the ON/OFF
switch
(
. After a short time restart
the appliance.
If the problem recurs, turn off the tap and pull
out the mains plug.
Call customer service and mention the error
code.
Display flashes
Door not closed properly.
Close the door. Ensure that no objects (uten-
sil, fragrance dispenser) are protruding over
the basket and preventing the door from clos-
ing.
Refill indicator for salt
H
and/
or rinse-aid
P
is lit.
No rinse aid.
Refill rinse aid.
No salt.
Refill with special salt.
Sensor does not detect salt tablets.
Use different special salt.
Refill indicator for salt
H
and/
or rinse-aid
P
is not lit.
Refill indicator switched off.
Activation/deactivation (see chapter Water sof-
tening system/Special salt or Rinse aid).
There is still enough special salt/rinse
aid available.
Check refill indicator, levels.
Water is left in the appliance
at the end of the programme.
Filter system or area under
the filters
1Z
is blocked.
Clean filters and area underneath (see Waste
water pump).
The programme has not yet ended.
Wait until programme ends or reset (see Termi-
nating the programme).