en
Installation instructions
38
¡
Do not install the appliance behind a decor-
ative door or the door of a kitchen unit.
There is a risk of overheating.
¡
Cut-out work on the units should be carried
out before installing the appliance. Remove
any shavings. Otherwise, the correct opera-
tion of electrical components may be ad-
versely affected.
¡
Only a licensed professional may connect
appliances without plugs. Damage caused
by incorrect connection is not covered un-
der the warranty.
WARNING ‒ Risk of injury!
Parts that are accessible during installation
may have sharp edges and may lead to cut-
ting injuries.
▶
Wear protective gloves.
WARNING ‒ Risk of fire!
It is dangerous to use an extended power
cord and non-approved adapters.
▶
Do not use extension cables or multiple
socket strips.
24.2 Scope of delivery
After unpacking all parts, check for any damage in
transit and completeness of the delivery.
24.3 Appliance dimensions
You will find the dimensions of the appliance here
24.4 Fitted units
This appliance is only intended to be fully fitted in a kit-
chen. It is not intended to be used as a tabletop appli-
ance or within a cupboard.
Ensure that the fitted cabinet behind the appliance
does not have a back panel. Maintain a clearance of at
least 45 mm between the wall and the cabinet base or
the rear panel of the cabinet situated above.
Do not cover the ventilation slots and air intake open-
ings.
Carry out all cut-out work on the kitchen unit and work-
top before fitting the appliance.
Remove the shavings.
24.5 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡
The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡
The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to the local regulations.
¡
The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡
Contact protection must be guaranteed by the in-
stallation.
¡
If the plug is no longer accessible following installa-
tion, an all-pole isolating switch with a contact dis-
tance of at least 3 mm must be present.
Great Britain and Australia
Do not connect using a 13 A plug or protect with a
13 A fuse. The appliance must be protected using a
16 A fuse. The appliance must always be disconnected
from the power supply when installation work is being
carried out. Contact protection must be guaranteed by
the installation.
Electrically connecting an appliance without a
protective contact plug
Note:
Only licensed specialists may connect the appli-
ance. Damage caused by incorrect connection is not
covered under the warranty.