 16.4 Secure installation

Follow these safety instructions when in-
stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space. 

Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.

It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.

In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.

Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.

Risk of poisoning from flue gases being
drawn back in.

If an extractor hood with an open-flued heat
production source is installed, the power
supply for the extractor hood must be
provided with a suitable safety switch.

Risk of poisoning from flue gases being
drawn back in.

Do not emit the exhaust air into a smoke or
exhaust gas flue that is in operation.

Do not emit the exhaust air into a shaft that
is used to ventilate installation rooms for
heat-producing appliances.

If the exhaust air is to be conveyed into a
smoke or exhaust gas flue, you must obtain
the consent of the heating engineer re-
sponsible.

WARNING ‒ Risk of suffocation!

Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.

Keep packaging material away from chil-
dren.

Do not let children play with packaging ma-
terial.

WARNING ‒ Risk of fire!

Grease deposits in the grease filter may catch
fire.

The specified safety clearances must be
complied with in order to prevent a build-up
of heat.

Observe the specifications for your cooking
appliances. If the installation instructions for
the cooking appliances specify a different
clearance, the larger of the two must al-
ways be provided for. If gas hobs and elec-
tric hobs are operated together, the largest
specified clearance applies.

The appliance must be installed with no
more than one side directly next to a high-
sided unit or a wall. The distance between
the appliance and wall or high-sided unit
must be at least 50 mm.

The grease deposits in the grease filter may
catch fire.

Never work with naked flames close to the
appliance (e.g. flambéing).

Do not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-remov-
able cover is present. There must be no fly-
ing sparks.

Summary of Contents for AW 27

Page 1: ...en User manual and installation instructions AW25 AW27 Extractor hood Gaggenau...

Page 2: ...en suring that the appliance works perfectly at its installation location Only use this appliance For extracting cooking vapour in private households and in enclosed spaces in a domestic environment u...

Page 3: ...filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flamb ing Do not install the appl...

Page 4: ...e appliance If the power cord of this appliance is dam aged it must be replaced by trained spe cialist staff An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug...

Page 5: ...sume any energy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on The cooking vapours and condensation are re duced Only use the addi...

Page 6: ...ccessories When using it in circulating air mode set the operat ing mode 7 Basic operation 7 1 Switching on the appliance Press a The appliance starts at fan setting 2 7 2 Switching off the appliance...

Page 7: ...and open it carefully 7 16 Saturation indicator If the grease filters or odour filters are saturated cor responding symbols flash after the appliance is switched off Note You can set the saturation i...

Page 8: ...ogle Play logo are trademarks of Google LLC 2 Open the Home Connect app and scan the follow ing QR code 3 Follow the instructions in the Home Connect app 8 2 Resetting the connection To reset the save...

Page 9: ...iciently for a long time it is important to clean and maintain it carefully 10 1 Cleaning products You can obtain suitable cleaning products from after sales service or the online shop WARNING Risk of...

Page 10: ...oth and hot soapy water 3 Dry with a soft cloth 10 4 Cleaning the magnetic mounting bracket ATTENTION Magnetic mounting brackets may come loose due to improper cleaning Do not use any sharp or pointed...

Page 11: ...light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed Removing the grease filter Page 10 1...

Page 12: ...btained from Customer Service for a period of at least 10 years from the date on which your appliance was placed on the market within the European Economic Area Note Under the terms of the manufacture...

Page 13: ...t page for your appliance Hereby BSH Hausger te GmbH declares that the ap pliance with Home Connect functionality is in compli ance with relevant statutory requirements 1 A detailed Declaration of Con...

Page 14: ...n mode 16 2 Appliance dimensions You will find the dimensions of the appliance here 16 3 Safety clearances Comply with the safety clearances for the appliance For Australia and New Zealand the minimum...

Page 15: ...the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flued heat production source is installed the po...

Page 16: ...appliance or the power cord is dam aged immediately unplug the power cord or switch off the fuse in the fuse box Call customer services Page 12 Incorrect repairs are dangerous Repairs to the applianc...

Page 17: ...r a wall The distance between the appliance and wall or high sided unit must be at least 50 mm The width of the extractor hood must correspond at least with the width of the hob To optimally detect th...

Page 18: ...as required 4 Tighten the safety screws When you install a flue cover install the bracket and hold it in place while screwing it in tight Piping Air extraction mode If you operate the appliance in ai...

Page 19: ...ining bracket for the flue duct to the wall 2 To separate the flue ducts remove the adhesive tape or the flue duct from the protective packaging 3 Remove any protective foil from both flue ducts 4 Use...

Page 20: ...4 81739 M nchen GERMANY www gaggenau com 9001640928 9001640928 en 030411 Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton...