SERIES CO-X EXHAUST PACKAGE
PREPARATION
1.
Check to make sure all components are complete and that there is no
concealed damage. If there is concealed damage, notify carrier
immediately. Car-Mon will not be responsible for equipment not inspected
on receipt from carrier.
2.
Review the instructions to make sure any materials needed for installation
not included by Car-Mon are provided by the installer.
3.
The main components for the system include a wall or ceiling platform, a
CMW direct drive fan, a single or dual tubing assembly with swivel or
swivel socket, gaskets, and hardware. The optional equipment may
include the BA Balancer, tubing sling, pull-up set, or wall
storage brackets.
INSTALLATION
1.
Make sure the mounting surfaces where the CO-X platform
and fan is to be mounted is level and plumb and can support
the weight of the entire unit. Wall mounted platforms are
installed "legs down" using the pre-drilled mounting holes.
Ceiling platforms should be securely attached to the building
structure using the mounting holes. Both units may also be
welded to the attached surface.
2.
Position CMW fan on platform using a gasket between the
fan and the platform, lining up the holes and making sure the
fan is in the proper discharge direction. Drop the 5/16 bolts
through the bolt holes.
3.
Attach the single or dual tube and swivel assembly to the
bottom of the platform using a gasket between the assembly
and the platform. Using the bolts from the fan above fasten
with the nuts provided. Attach the fan discharge to the
ductwork. For attachment of the optional balancer, see the
instructions at the end of this manual.
4.
Wire the fan motor. See the fan wiring diagrams on Page 2.
Make sure the diagram matches the model number on the motor plate. If it
does not, consult the wiring diagram on the motor plate, or call customer
service at the factory. The installation is now complete and the system can
be tested. When testing briefly start and stop the motor to see if the rotation
of the fan is correct. If it is not, recheck the wiring of the fan. After checking
rotation, run system for several minutes to check for any vibration or excess
noise, and to see if there is good air flow through the tube(s).
OPERATION
1.
Attach the exhaust adapter the vehicle tailpipe. The vehicle SHOULD NOT
be running while the attachment is made. Make sure the fan on the system
is running and air is going through the tubing before the vehicle is started.
Starting a vehicle with a exhaust adapter attached and the fan not running is
unsafe and may cause damage to the tubing drop. After servicing, shut off the vehicle, leaving the
tubing assembly attached and the fan running. Continue to run the fan for a short time to let the
ambient air running through the tube cool it down before detaching it. Care should always be taken
when removing the tubing assembly as it can remain hot for a period of time if not cooled with
ambient air.