Providing all maintenance conditions have been met, follow this systematic approach to diagnosis.
1. MORE THAN ONE PULL IS REQUIRED TO BREAK FASTENER WHEN THE ACTUATOR ASSEMBLY (510127) IS DEPRESSED.
a) Jaws are stripped or packed with chips. Clean or replace.
b) Incorrect nose tip.
2. FASTENER STEM JAMMED IN NOSE ASSEMBLY.
a) Nose assembly components require service.
DISCONNECT AIR FROM TOOL
, remove the nose assembly from the tool
and disassemble. Replace worn or broken parts. Clean the surface the jaws ride on.
b) Stems lodged side by side in the follower. Disassemble, remove stems, and reassemble. (See proper nose assembly data
sheet for detailed instructions).
c) Incorrect follower.
TROUBLESHOOTING