background image

Elnur

 

powered by Gabarrón  |  INGENIUM WIFI Thermal Radiators  |  Installation Guide

2

•  The warranty of the heater will not cover any  

  damage caused by non-observance of any of  

  these instructions.
•   The instructions should be retained for future  

  reference. This guide must be kept and given to  

  any new owner.
•   This appliance can be used by children aged from  

  8 years and above and persons with reduced  

  physical, sensory or mental capabilities or lack of  

  experience and knowledge if they have been given  

  supervision or instruction concerning the use of the  

  appliance in a safe way and understand the hazards  

  involved. Children must not play with the appliance.  

  Cleaning and user maintenance must not be made  

  by children without supervision.
•   Children aged from 3 years and less than 8 years  

  shall only switch on/off the appliance provided  

  that it has been placed or installed in its intended  

  normal operating position and they have been  

  given supervision or instruction concerning use of  

  the appliance in a safe way and understand the  

  hazards involved. Children aged from 3 years and  

  less than 8 years shall not plug in, regulate and  

  clean the appliance or perform user maintenance.
•   Children of less than 3 years should be kept away  

  unless continuously supervised.
•   Please check that the voltage in the rating label  

  fits the power supply.
•   The use of these heaters is forbidden in any area  

  where there is a presence of gases, explosives or  

  inflammable objects.
•   Do not use this heater to dry clothes. Do not cover  

  this heater or put objects in contact with it.
•   Neither the connecting cable nor any other object  

  must come into contact with the hot unit.
•   Do not cover this heater at any time.
•   The air outlet at the top of the thermal radiator and  

  the air inlet at the bottom are provided to ensure  

  the most efficient operation of the appliance. They  

  also protect the heater from overheating; therefore,  

  it is essential that at no time are they covered.
•   This heater should be switched off at the isolating  

  switch before any repair work is carried out.

•   The installation must be carried out in accordance  

  with the current electrical regulations.
•   Should the heater be moved and reinstalled it is  

  essential that the work is carried out by a fully  

  qualified technician.
•   The heater should not be installed just below an  

  electrical socket.
•   The appliance must be installed in such a way that  

  it is impossible for anyone using a bath or shower, to  

  touch the controls.
•   The heater is fitted with a flexible cable size 3 x  

  1.00 mm² for electrical connection. It may be used  

  to connect the heater to the fixed wiring of the  

  premised through a suitable connection box    

  positioned adjacent to the heater.
•   The supply circuit to the heater must incorporate  

  a double pole isolating switch having a contact  

  separation of at least 3 mm.
•   If the flexible power cable for this unit is damaged,  

  it may only be replaced by a repair workshop   

  recognised by the manufacturer, as special tools  

  are necessary.
•   This appliance must be earthed.
•   All models are supplied with an electrical interrupt  

  cut-out. This will switch off the heater if, for any  

  reason, it overheats. Should the cut-out operate,  

  turn the heater off and remove the cause of the  

  overheating. The cut-out will be reset automatically.
•   This heater is filled with a precise quantity of special  

  oil. Repairs requiring opening of the oil container are  

  only to be made by the manufacturer or his service  

  agent who should be contacted if there is an oil  

 leakage.
•   Regulations concerning the disposal of oil when  

  scrapping the appliance have to be followed.
•   The presence of air particles of smoke, dust and  

  other pollutants could, in time, discolour the walls  

  and surfaces around the heater.
•   CAUTION — Some parts of this product can become  

  very hot and cause burns. Particular attention must  

  be given when children and vulnerable people  

  are present.

1.  IMPORTANT INFORMATION

CAUTION: Some parts of this product can become hot and cause burns. Particular 

attention must be given when children and vulnerable people are present.

!

Summary of Contents for Elnur INGENIUM Series

Page 1: ...ease read these instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide INGENIUM WIFI Thermal Radiators RD4W RD6W RD8W RD10W RD12W RD14...

Page 2: ...o time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical...

Page 3: ...as furniture curtains etc The rest of clearances required to maintain are indicated on the figure opposite 2 2 INSTALLATION INSTRUCTIONS Open the package and check that it is the correct model and it...

Page 4: ...y Temperature setpoint Heating on indicator G Control Hub connection indicator Current set point temperature in AUTO mode Main switch All models are equipped with one switch on the back surface allowi...

Page 5: ...button 0 00 0 00 0 0 00 0 00 00 1 1 0 00 9 00 0 00 0 00 0 0 00 0 00 00 1 1 0 00 9 00 If the device is associated with a G Control Hub the adjustment of time is removed and the time in the G Control H...

Page 6: ...o to do this Press Release the Config Prog button until the display shows the flashing temperature symbol Now press the OK Mode button to select the temperature you want to change COMFORT or ECONOMIC...

Page 7: ...he radiator is installed using this information to turn on the heating element in advance in order to reach the set point temperature at the desired time It will be shown in the displays as follows No...

Page 8: ...the Config Prog button for 5 seconds the first parameter C1 will be displayed To select the next parameter press the button To modify the value of the parameters press the OK Mode button Then use the...

Page 9: ...of the unit press OK Mode button to cancel it any other button can be pressed 7 ON OFF With the parameter in ON the open window detection is activated C6 Adaptive Start Control ON OFF With the parame...

Page 10: ...Contact the after sales service Err1 Err2 Err3 Err4 message is displayed Contact the after sales service Time settings are lost There was electric supply shortage or the unit has been disconnected by...

Page 11: ...iac Relay All models are equipped with control function through G Control Hub connected to the network 10 MAIN COMPONENTS LIST Right side plastic case ref 46102362 500 W Heating Element ref 30100142 L...

Page 12: ...12 11 WIRING 9 Electronic Control PCB Only RD14W model ref 46102310 1250 W Heating Element ref 30100172 Main Switch ref 46100530 1500 W Heating Element ref 30100182 Temperature sensor ref 46102195 200...

Page 13: ...00 0 000 kW At minimum heat output el min 0 000 0 000 0 000 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 0 0005 0 0005 0 0005 kW MODEL S GABARRON RD4W RD6W RD8W RD10W RD12W RD14W Er...

Page 14: ...ma adecuada Para obtener informaci n m s detallada sobre el reciclaje de este producto p ngase en contacto con la administraci n de su ciudad con su servicio de desechos del hogar o con la tienda dond...

Reviews: