Please read these instructions carefully before installing or using this appliance for the first time.
Installation Instructions
& User Guide
INGENIUM
WIFI Thermal Radiators
RD4W | RD6W | RD8W | RD10W | RD12W | RD14W
Page 1: ...ease read these instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide INGENIUM WIFI Thermal Radiators RD4W RD6W RD8W RD10W RD12W RD14...
Page 2: ...o time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical...
Page 3: ...as furniture curtains etc The rest of clearances required to maintain are indicated on the figure opposite 2 2 INSTALLATION INSTRUCTIONS Open the package and check that it is the correct model and it...
Page 4: ...y Temperature setpoint Heating on indicator G Control Hub connection indicator Current set point temperature in AUTO mode Main switch All models are equipped with one switch on the back surface allowi...
Page 5: ...button 0 00 0 00 0 0 00 0 00 00 1 1 0 00 9 00 0 00 0 00 0 0 00 0 00 00 1 1 0 00 9 00 If the device is associated with a G Control Hub the adjustment of time is removed and the time in the G Control H...
Page 6: ...o to do this Press Release the Config Prog button until the display shows the flashing temperature symbol Now press the OK Mode button to select the temperature you want to change COMFORT or ECONOMIC...
Page 7: ...he radiator is installed using this information to turn on the heating element in advance in order to reach the set point temperature at the desired time It will be shown in the displays as follows No...
Page 8: ...the Config Prog button for 5 seconds the first parameter C1 will be displayed To select the next parameter press the button To modify the value of the parameters press the OK Mode button Then use the...
Page 9: ...of the unit press OK Mode button to cancel it any other button can be pressed 7 ON OFF With the parameter in ON the open window detection is activated C6 Adaptive Start Control ON OFF With the parame...
Page 10: ...Contact the after sales service Err1 Err2 Err3 Err4 message is displayed Contact the after sales service Time settings are lost There was electric supply shortage or the unit has been disconnected by...
Page 11: ...iac Relay All models are equipped with control function through G Control Hub connected to the network 10 MAIN COMPONENTS LIST Right side plastic case ref 46102362 500 W Heating Element ref 30100142 L...
Page 12: ...12 11 WIRING 9 Electronic Control PCB Only RD14W model ref 46102310 1250 W Heating Element ref 30100172 Main Switch ref 46100530 1500 W Heating Element ref 30100182 Temperature sensor ref 46102195 200...
Page 13: ...00 0 000 kW At minimum heat output el min 0 000 0 000 0 000 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 0 0005 0 0005 0 0005 kW MODEL S GABARRON RD4W RD6W RD8W RD10W RD12W RD14W Er...
Page 14: ...ma adecuada Para obtener informaci n m s detallada sobre el reciclaje de este producto p ngase en contacto con la administraci n de su ciudad con su servicio de desechos del hogar o con la tienda dond...