Installation Instructions
7
Note: Two electrical supplies needed.
Economy
and
24hr
supply.
Connection and Disconnection
Each ECOHHR storage heaters has its own power
switch and is located on the right side panel. The power
switch is used to turn the heater ON and OFF.
If this switch is turned OFF then the storage heater will
not take a charge when the off peak supply is on and
will not give out any heat. Therefore it is important to
make sure this is turned ON at all times.
Each ECOHHR storage heater requires two electrical
supplies. One is an economy tariff supply (off peak or
restricted supply) and the other is a 24hr supply (on
peak or unrestricted supply).
Connection from the economy supply (off peak or
restricted supply) to the heater should be via a 20Amp
double pole isolator switch.
Connection from the 24hr supply (on peak or
unrestricted supply) to the heater should be via a fused
double pole isolator switch or a fused RCD isolator
switch, depending on the installation.
User Control Panel
You will find the keypad on the top right side on the
heater. This easy to use keypad only has four buttons,
however these four button can be use in different ways
to give you many functions and will be explained in
more detail in later sections.
Basic Key functions:
This button is used to set the
'Comfort'
temperature. Default is 21°C.
This button is used to set the
'Economy'
temperature. Default is 18°C.
This button is used to decrease values.
This button is used to increase values.
& Pressing these buttons together will allow
you to set the Day and Time.
& Pressing these buttons together will allow
you to set the weekly program.