Introduction Foreword:

Thank you that you have chosen the G-Systems Engineering Ltd 16A fan controller 
product.

The 16A fan controller is a climate controller which can measure the air temperature 
humidity and water temperature. The controller integrates several measurements 
simultaneously and continuously controls devices such as intake- and exhaust fans and 2 
switched channels can be individually and user definied programmed on / off. The 16A fan 
controller controls based on the measurement data all functions, depending on the model 
saves all setpoints and actual values to an external USB memory stick in a .csv format 
(comma-separated values). These values can be evaluated on a computer at a later time, 
or with the free of charge GSE Growthanalizer software.

Technical specifications:

Operating voltage: 230V / 50Hz
Depending on the country the maximum power rating of the power-cord is variable:
VDE L typ max: 16A, Schuko 
VDE F type max: 16A, France
VDE E type max:13A, Switzerland
VDE U type max 13A, England

Loading of the individual outputs: 
Intake fan max:

10A 2300W cos 1

Exhaust fan max :  10A 2300W cos 1
Exit 1 max: 

10A 2300W cos 1

Exit 2 max: 

10A 2300W cos 1

The sum of all the currents can not exceed prescribed maximum current of the country 
socket!

Assembly:

Mount the 16A fan controller with the included mounting bracket to a non-flammable 
surface such as brick concrete and never on wood, plastic carboard, etc. Make sure that 
on your choice of the place have sufficient ventilation in the location and the heat can be 
dissipated. Avoid small unventilated rooms or cabinets. Improper installation will result a 
overheating of the controller!

Operation of the keypad: 

The controller is operated by four menu keys.

With the arrow keys UP and DOWN the various menu lines can be selected. Press 

page 2 of 15

Summary of Contents for 16A

Page 1: ...art 2 7 Main screen part 3 7 Main menu 7 Submenu ventilator settings 8 Settings of switched outputs EXIT1 10 Disabled 10 Output Sensor 1 heat 10 Output sensor 1 cool 11 Output sensor 1 humidify moistu...

Page 2: ...tage 230V 50Hz Depending on the country the maximum power rating of the power cord is variable VDE L typ max 16A Schuko VDE F type max 16A France VDE E type max 13A Switzerland VDE U type max 13A Engl...

Page 3: ...keys you don t have to confirm with ENTER the values get stored with SAVE EXIT All values get stored in an internal memory and are also after a power failure or prolonged disconnection available Time...

Page 4: ...2 5 Temperature LED 6 Exit 1 LED 7 Humidity LED 8 Day night LED 9 Alarm LED 10 Exit 2 LED 11 UP arrow 12 DOWN arrow 13 SAVE EXIT 14 ENTER 15 Powersupply 16 Sensor cable for temperature and humidity on...

Page 5: ...Menu structure page 5 of 15...

Page 6: ...Function diagram page 6 of 15...

Page 7: ...or 1 max T2 Temperature sensor 2 max Alarms of underrun minimum values T1 Temperature sensor 1 min RH Humidity sensor 1 min T1 Temperature sensor 2 min Confirm with the SAVE EXIT button an alarm The 9...

Page 8: ...Set temperature Temperature setting 2 Set humidity Humidity setting 3 Fan settings Ventilator Setting Scroll with the UP DOWN keys to display the below information 1 Fan day Ventilation day 2 Fan nigh...

Page 9: ...upply air fan don t have a minimum speed value and will turn off when the temperature and humidity undercuts the set value By setting of the minimum speed value at the exhaust fan you avoid odours esc...

Page 10: ...utput timer Scroll with UP DOWN buttons to the desired function and confirm with ENTER If a function has already been selected you can use set value to change the values If you like to switch to anoth...

Page 11: ...the cooling capacity becomes 24 0 C 2 0 C 26 0 C and by reaching 24 0 C is off again This contact will remain off until the value rises above 26 0 C Output sensor 1 humidify moisturise The procedure i...

Page 12: ...to reach the selection menu Set Exit 1 To delete a program step set the time back to 00 00 00 00 00 When you have finished programming the Exit 1 press SAVE EXIT to return to the main menu Settings o...

Page 13: ...r Here you will see the current value of the light sensor this occurs in daytime almost 100 As darker it is as lower is this value Set the switching threshold press again ENTER the value begins to bli...

Page 14: ...ery 5minutes to your USB memory stick Push ENTER button the value begins to blink change the value with the UP DOWN buttons save it with SAVE EXIT General limitations All firmware versions support BOM...

Page 15: ...Confirm with ENTER The controller reset all the data back to the original factory settings except time and date settings page 15 of 15...

Reviews: