Time and date settings:

Press ENTER to set date and time in the sub menu "Set date / time". As first you have to 
set the date in the format day, month, year. After this set the time in hours and minutes. 
The first day field starts to blink, now you can set the day with the buttons UP / DOWN. 
Press ENTER to confirm and move to the next months field. Repeat the procedure and 
make set the year. Press ENTER again and set the hours field, repeat the procedure for 
the minutes. Save the settings you have made with SAVE / EXIT and return to the 
selection menu "General settings."

Language settings:

Go to the menu "Language Settings.Press ENTER to set Languages in the sub menu "Set 
language" The preferred language starts blinking. Select with the UP / DOWN buttons the 
desired language, confirm with SAVE / EXIT. The new language is activated now.

Light sensor settings:

Go to the menu "Set photosensor". This is used for day> night or night> day change over. 
Depending on the state day or night, the controller selects the appropriate settings you 
have set previously in the controller. Here you will see the current value of the light sensor,
this occurs in daytime almost 100%. As darker it is, as lower is this value. Set the switching
threshold. press again ENTER the value begins to blink, change the value with UP / 
DOWN buttons and save with SAVE / EXIT to return to the light sensor menu. Now select 
the "Switch time". The switching time is a time delay which starts a count down after 
reaching the light sensor level. During this time the switching threshold remains. Only after
expiration of the delay time, the controller will perform the switching threshold. If this time 
gets interrupted, the time delay starts to count down again from beginning. This function is 
used to prevent an immediate change over e.g: A door gets opened briefly. Press ENTER, 
the value starts to blink, change the value with UP / DOWN save it with SAVE / EXIT.

LCD Display settings:

Go to the sub menu “Set display” this is used to change the state of the LCD back light. 
You have the choice of Automatic, on or off. Change the value with UP / DOWN buttons 
and save it with SAVE / EXIT.

Alarm settings:

Here you can set the maximal and minimal alarm values of the sensors. In case of an over

page 13 of 15

Photosensor  35%
Switch at:   50%
switch time 300s

LCD back light
       automatic
              on
             off

Summary of Contents for 16A

Page 1: ...art 2 7 Main screen part 3 7 Main menu 7 Submenu ventilator settings 8 Settings of switched outputs EXIT1 10 Disabled 10 Output Sensor 1 heat 10 Output sensor 1 cool 11 Output sensor 1 humidify moistu...

Page 2: ...tage 230V 50Hz Depending on the country the maximum power rating of the power cord is variable VDE L typ max 16A Schuko VDE F type max 16A France VDE E type max 13A Switzerland VDE U type max 13A Engl...

Page 3: ...keys you don t have to confirm with ENTER the values get stored with SAVE EXIT All values get stored in an internal memory and are also after a power failure or prolonged disconnection available Time...

Page 4: ...2 5 Temperature LED 6 Exit 1 LED 7 Humidity LED 8 Day night LED 9 Alarm LED 10 Exit 2 LED 11 UP arrow 12 DOWN arrow 13 SAVE EXIT 14 ENTER 15 Powersupply 16 Sensor cable for temperature and humidity on...

Page 5: ...Menu structure page 5 of 15...

Page 6: ...Function diagram page 6 of 15...

Page 7: ...or 1 max T2 Temperature sensor 2 max Alarms of underrun minimum values T1 Temperature sensor 1 min RH Humidity sensor 1 min T1 Temperature sensor 2 min Confirm with the SAVE EXIT button an alarm The 9...

Page 8: ...Set temperature Temperature setting 2 Set humidity Humidity setting 3 Fan settings Ventilator Setting Scroll with the UP DOWN keys to display the below information 1 Fan day Ventilation day 2 Fan nigh...

Page 9: ...upply air fan don t have a minimum speed value and will turn off when the temperature and humidity undercuts the set value By setting of the minimum speed value at the exhaust fan you avoid odours esc...

Page 10: ...utput timer Scroll with UP DOWN buttons to the desired function and confirm with ENTER If a function has already been selected you can use set value to change the values If you like to switch to anoth...

Page 11: ...the cooling capacity becomes 24 0 C 2 0 C 26 0 C and by reaching 24 0 C is off again This contact will remain off until the value rises above 26 0 C Output sensor 1 humidify moisturise The procedure i...

Page 12: ...to reach the selection menu Set Exit 1 To delete a program step set the time back to 00 00 00 00 00 When you have finished programming the Exit 1 press SAVE EXIT to return to the main menu Settings o...

Page 13: ...r Here you will see the current value of the light sensor this occurs in daytime almost 100 As darker it is as lower is this value Set the switching threshold press again ENTER the value begins to bli...

Page 14: ...ery 5minutes to your USB memory stick Push ENTER button the value begins to blink change the value with the UP DOWN buttons save it with SAVE EXIT General limitations All firmware versions support BOM...

Page 15: ...Confirm with ENTER The controller reset all the data back to the original factory settings except time and date settings page 15 of 15...

Reviews: