Chapter 2 Installation
Chapter 2 Installation
2 2 Mounting
2 2 Mounting
2 1 Unpacking
2 1 Unpacking
Upon receipt of the shipment remove the unit from the carton and inspect the
unit for shipping damage.
If any damage due to transit , report and claim with the carrier.
Write down the model number, serial number, and date code for future reference
when corresponding with our ser vice center. The serial number (S/N) and date
code (D/C) are labeled on the box and the housing of control.
Upon receipt of the shipment remove the unit from the carton and inspect the
unit for shipping damage.
If any damage due to transit , report and claim with the carrier.
Write down the model number, serial number, and date code for future reference
when corresponding with our ser vice center. The serial number (S/N) and date
code (D/C) are labeled on the box and the housing of control.
Make panel cutout to dimension shown in Figure 2.1.
Make panel cutout to dimension shown in Figure 2.1.
Take both mounting clamps away and insert the controller into panel cutout.
Install the mounting clamps back. Gently tighten the screws in the clamp till the
controller front panels is fitted snugly in the cutout.
Take both mounting clamps away and insert the controller into panel cutout.
Install the mounting clamps back. Gently tighten the screws in the clamp till the
controller front panels is fitted snugly in the cutout.
Figure 2.1 Mounting Dimensions
Figure 2.1 Mounting Dimensions
Dangerous voltages capable of causing death are sometimes
present
in this instrument. Before installation or beginning any troubleshooting
procedures the power to all equipment must be switched off and isolated.
Units suspected of being faulty must be disconnected and removed to a
properly equipped workshop for testing and repair. Component replacement
Dangerous voltages capable of causing death are sometimes
present
in this instrument. Before installation or beginning any troubleshooting
procedures the power to all equipment must be switched off and isolated.
Units suspected of being faulty must be disconnected and removed to a
properly equipped workshop for testing and repair. Component replacement
To minimize the possibility of fire or shock hazards, do not expose this
instrument to rain or excessive moisture.
To minimize the possibility of fire or shock hazards, do not expose this
instrument to rain or excessive moisture.
Do not use this instrument in areas under hazardous conditions such
as excessive shock, vibration, dirt, moisture, corrosive gases or oil. The
ambient temperature of the areas should not exceed the maximum rating
Do not use this instrument in areas under hazardous conditions such
as excessive shock, vibration, dirt, moisture, corrosive gases or oil. The
ambient temperature of the areas should not exceed the maximum rating
Panel
2.95”
SCREW
MOUNTING
CLAMP
Panel cutout
Panel cutout
1.77”
1.77”
.53”
.43”
UM9300 2.0
UM9300 2.0
15