140
< Model menu (Airplane/Glider/Multicopter Functions) >
Butterfly
[Corresponding model type]: Glider, 2 ailerons or more
This function allows powerful brake operation
by simultaneously raising the left and right
ailerons and lowering the flaps (camber flap,
EUDNHÀDS
This setting will allow the ailerons to be raised
while the flaps are simultaneously lowered.
Butterfly (crow) produces an extremely efficient
landing configuration by accomplishing the
following:
1. Slow the aircraft’s velocity.
2. Provide washout at the wing tips to reduce
the tendency to tip stall.
3. Create more lift toward the center of the
wing allowing it to
Á
y at a slower speed.
ŏ
Mixing during
Á
ight can be turned ON/OFF by
setting a switch. (Always ON at [--] setting)
ŏ
The butter
Á
y operation reference point can be
offset. When the screen is tapped with the offset
item selected when operated to the position to
be changed, the reference point is offset. If the
reference point is offset too much, unexpected
operation may be performed.
ŏ
The ailerons and
Á
aps operation speed can be
adjusted. (In side/Out side)
ŏ
A delay can be set for each condition. A cut
switch which can turn OFF the delay function can
also be set.
ŏ
The differential rate can be adjusted.
*When servo binding occurs when setting the ailerons and
ÀDSVLQEXWWHUÀ\PL[LQJXVHWKH$)5IXQFWLRQWRDGMXVWWKH
rate.
ŏ
Select [Butterfly] at the model
menu and call the setup screen
shown below.
*The display screen is an example. The actual
screen depends on the model type.
W h e n u s i n g t h i s
function, Tap [INH].
(ON is displayed.)
Condition group/single
mode selection (Gr. /
Sngl)
The ON/OFF switch of
mixing is chosen.
When offsetting the butterfly operation reference point,
operate to the point you want to change and then touch
the Offset button. The reference point displays 0%.
When [Yes] is touched, the reference point is changed.
Then, is "Initialized elevator curve?" is heard, it chooses
in which.
Condition delay setting
Condition delay cut
switch
To next page
The differential rate
can be adjusted.
In speed
Out speed
(First)0 〜 27(Slowly)
(To elevator curve setup screen)
Elevator rate
adjustment
Select the Mixing Rate
AIL and FLP box. Adjust
the mixing rates.
*The display screen is an example. The actual
screen depends on the Model Type.
ŏ
Return to Model menu