Fail-Safe position setting
While holding the wheel or trig-
ger, tap the Fail-Safe position
button.
Battery fail safe function
OFF, ON
Initial value: OFF
Fail safe mode
Off, Hold, Fail-safe
59
Fu
nc
tio
n
Fail-Safe/ Battery Fail-Safe Function
1
(Battery fail safe function ON/OFF)
Tap B-F /S (ON) or (OFF) of each channel to select ON / OFF.
2
(Battery fail safe voltage setting)
Tap the voltage display of battery fail safe
voltage. Value input buttons appear on the
Fail-Sahe menu screen.
Use the [+] or [-] button to select the voltage.
* Voltage setting is not possible with the S - FHSS sys-
tem fixed at 3.8 V.
* Since FASST R604 Series receivers are not for high
voltage use, the use of LiFe and Li-Po batteries is pro-
hibited. Therefore, the 4.75v and 5.5v settings
are prohibited. The 5.5 V setting of the FASST
system can only be used by the receiver with
R614FS (FSE).
B-F/S function ON/OFF & Battery Fail-safe voltage setting
Battery Fail-safe Voltage
T-FHSS SR/T-FHSS
3.8,4.0,4.2,4.4,4.6,4.8,5.0,
5.3,5.6,5.9,6.2,6.5,6.8,7.1,7.4V
FASST
3.5,3.8,4.4,4.75
5.5V(Only R614)
S-FHSS
Only 3.8V
Example:
Ni-MH /Ni-Cd 4cell---3.8V
Ni-MH /Ni-Cd 6cell---4.4V
LiFe 2cell---4.75/4.8V
Li-Po 2cell---5.5/5.6V
When the receiver power supply of an electric car uses a common power supply from an ESC, we recommend that this function be set
to OFF because the voltage supplied to the receiver may drop momentarily and the battery fail safe function may be activated.
(Preparation)
- Tap the fail safe part of the channel you want to set.
The mode list appears on the Fail-safe menu
screen.
1
(Mode selection)
Tap from the list and select the mode. To cancel,
tap [Cancel].
(Each channel can be individually set.)
Fail safe mode selection
1
(Servo position setup)
Tap the F/S button of the channel you want to set, and set that
channel to the [F/S] mode.
Hold the corresponding steering wheel, throttle trigger, or oth-
er control in the position you want the servo to move to when
the fail safe function is activated, and tap the F/S position but-
ton.
That position is displayed in percentage.
2
When finished, return to the Linkage menu screen by pressing
the HOME button.
Fail safe function setup
2
When finished with hold or off mode setting, return to the Linkage menu screen by pressing
the HOME button. When setting fail safe, set the servo position by the following method.
3
When finished, return to the Linkage menu screen by pressing the HOME button.
1M23N32602_7PX_E.indb 59
2017/08/02 14:17:18