4
2.
WIRING
2.1
Wiring Outline
Connect the power cable, transducer cables, sensor cable, network cable and ground wire to their
respective locations on the network fish finder. See the next page for how to connect the trans-
ducer cable.
Ground
Connect a ground wire (IV-2 sq, local supply) between the
ground terminal and ship’s ground to prevent interference to
the sounder picture. Make the length of the wire as short as
possible. For FRP vessels, install a ground plate that mea-
sures approx. 20 cm by 30 cm on the outside of the hull bot-
tom and connect the ground wire there.
White
Black
Ground wire
(IV-2 sq)
DFF1-UHD
MOD-Z072-050+, 5 m
(option: 2/10 m)
TZT9/TZT14/
TZTBB
GROUND
MJ-A3SPF0013-035C
(3.5 m)
External
KP
Temperature or
Speed/Temperature
Sensor*
Transducer
BATTERY
12 - 24 VDC
Shield (green)
* For no connection,
cover connector
with supplied cap.
To HUB-101
CAUTION
Ground the equipment
to prevent mutual
interference.
Summary of Contents for NXT-600
Page 1: ...NETWORK FISH FINDER DFF1 UHD OPERATOR S MANUAL www furuno com Model ...
Page 2: ......
Page 38: ...26 Aug 2014 H MAKI D 1 ...