6. INSTALLATION AND WIRING
6-5
6.2
Wiring
A maximum of six control units can be connected. The TB8 port of the processor unit
has two connection lines for the control unit. Three control units can be connected in
a daisy chain connection per each connection line.
The rear side of the control unit
Ground terminal
To processor unit,
other control unit, or
terminator
Cable assy. (BD-07AFFM-LR-100/150) or
Terminator (BD-07AFFM-LR7001)
Ground wire
(IV-1.25 sq.)
Ship's ground
To processor unit,
other control unit, or
terminator
Signal connector:
Each I/O interface is same.