1.2.1
How to power the system
Press the
key to power the system. A beep sounds and the result of the start up
test appears followed by the start screen. The startup test checks the ROM, RAM and
backup of the processor unit and control unit. The test also checks for the presence of
heading from the heading sensor and rudder angle information from the rudder refer-
ence unit.
Note:
The content of the startup test changes according to your system configuration.
If “NG” appears for any item, an error message, shown in the table below, appears.
Follow the information provided in the message to restore normal operation. If you
cannot restore normal operation, contact your dealer.
1.2.2
How to power off the system
Long press the
key to power off the system. While pressing the key, the display
shows the number of seconds remaining until the power is turned off.
Error message
Meaning
System has failed startup test. Please contact a lo-
cal FURUNO representative for repair if problem
re-occurs.
The system has failed the start up
test.
Back-up data is corrupt factory defaults will be re-
stored (processor). Push any key to continue.
Backup data of the processor unit
is corrupted.
Back-up data is corrupt factory defaults will be re-
stored (controller). Push any key to continue.
Backup data of the control unit is
corrupted.
Cannot receive heading data. Please check the
heading sensor.
Problem with heading sensor.
EVC Interface has failed startup test. Please con-
tact a local FURUNO representative for repair.
Push any key to continue.
System error of the IPS interface
unit or NMEA data converter. Turn
off the autopilot, contact your deal-
er.
No connect EVC Interface. Please check the EVC
Interface. Push check the heading sensor.
The IPS interface unit or NMEA
data converter is not connected.
Check the connection with IPS in-
terface unit or NMEA data convert-
er.
NAVpilot-711C Startup Test
Processor 6454007-**.**
Controller 6454011-**.**
ROM RAM Backup
Processor
OK OK
OK
Controller
OK OK
OK
Heading Sensor OK xx.x
°
RRU
OK P12.3
°
Controller ID: 1
**.** : Program version no.
Summary of Contents for NAVpilot 711C
Page 1: ...AUTO PILOT NAVpilot 711C OPERATOR S MANUAL www furuno com Model...
Page 66: ...2 STEERING MODES 2 42 This page is intentionally left blank...
Page 104: ...5 MAINTENANCE TROUBLESHOOTING 5 16 This page is intentionally left blank...
Page 158: ...7 INITIAL SETTINGS 7 46 This page is intentionally left blank...
Page 168: ...4 Oct 2013 H MAKI D 1...
Page 174: ......