3. ALARMS
3-6
3.10
Water Temperature Alarm
The water temperature alarm warns you when the water temperature is within, out-
side, over or under the temperature range setting. Also, it is available to alert you when
temperature changes over the value set within a minute. Requires a water tempera-
ture sensor.
1. Open the [Alarm] menu.
2. Rotate the
Course control
knob to select the current setting for
[Temp Alarm] then push the knob.
The window shown right appears.
3. Rotate the
Course control
knob to select an option then push
the knob. For [OFF], go to step 6.
[OFF]: Turn the alarm off.
[Under]: Alarm sounds when water temperature is less than the
set value.
[Over]: Alarm sounds when water temperature is higher than the set value.
[Inside]: Alarm sounds when water temperature is within the range set.
[Out of Range]: Alarm sounds when water temperature is outside the range set.
[Shear]: Alarm sounds when the temperature changes over the value set within a
minute.
4. Rotate the
Course control
knob to select the current setting value then push the
knob.
5. Push the
Course control
knob to set the value then push the knob.
[Over], [Under], [Shear]: Set a value.
[Inside], [Out of Range]: Set the upper and lower limits for the alarm.
6. Press the
key three times to close the menu.
OFF
Under
Over
Inside
Out of Range
Shear
Summary of Contents for NAVpilot 711C
Page 1: ...AUTO PILOT NAVpilot 711C OPERATOR S MANUAL www furuno com Model...
Page 66: ...2 STEERING MODES 2 42 This page is intentionally left blank...
Page 104: ...5 MAINTENANCE TROUBLESHOOTING 5 16 This page is intentionally left blank...
Page 158: ...7 INITIAL SETTINGS 7 46 This page is intentionally left blank...
Page 168: ...4 Oct 2013 H MAKI D 1...
Page 174: ......