3. ADJUSTMENTS AND CHECKS
3-5
3.7
How to Check the Hull Unit
Do not transmit while doing this procedure.
How to enable transmission
The default transmission state is OFF. Enable transmission as shown in the procedure
below. NEVER transmit when the vessel is in dry dock, to prevent damage to the
transducer.
1. Turn on the power and press the
MENU/ESC
key to open the menu.
2. Use the trackball to select [Others] then right-click.
3. Select [Initial Setting] then left-click.
4. Select [Test] then left-click.
5. Select [TX] then left-click.
6. Select [On] then left-click.
7. Select [Quit] then left-click.
8. Select [Quit] on the topmost menu then left-click.
Edit User Program...
ES Setting...
2D-Map Disp Setting...
Erase Marks...
Wheel Setting...
Mid Key Setting...
Display Setting...
Alarm & Audio...
Register...
Record/Recall...
Initial Setting...
: Fixed Position
Others
Quit
Initial Setting
Quit
Menu Box Transp. : OFF
Monitor Setting...
Data Display...
Mark Display...
Mark Size
Stabilization...
Test...
Initialization...
Test
Quit
Board Test...
: Execute
Panel Test...
: Execute
Test Pattern... : Execute
RX Test...
: Execute
Noise Test...
: Execute
TX :
OFF
Summary of Contents for FSV-85
Page 28: ...1 HOW TO INSTALL THE SYSTEM 1 20 This page is intentionally left blank ...
Page 56: ...3 ADJUSTMENTS AND CHECKS 3 10 This page is intentionally left blank ...
Page 67: ...12 Nov 2010 Y NISHIYAMA D 1 ...
Page 68: ...4 Feb 2011 Y NISHIYAMA D 2 ...
Page 69: ...5 Nov 2010 Y NISHIYAMA D 3 ...
Page 70: ...4 Apr 2014 H MAKI D 4 ...
Page 71: ...6 Jul 2012 Y NISHIYAMA D 5 ...
Page 72: ...Nov 22 06 T Matsuguchi D 6 ...
Page 73: ...22 Apr 2013 Y NISHIYAMA D 7 ...
Page 74: ...22 Apr 2013 Y NISHIYAMA D 8 ...
Page 75: ...26 Nov 2010 Y NISHIYAMA D 9 ...
Page 76: ...27 Dec 2010 Y NISHIYAMA D 10 ...
Page 77: ...Nov 22 06T Matsuguchi D 11 ...
Page 78: ...D 12 ...
Page 79: ...29 Mar 2011 Y NISHIYAMA D 13 ...
Page 80: ...13 Sep 2011 Y NISHIYAMA D 14 ...
Page 81: ...13 Sep 2011 Y NISHIYAMA D 15 ...
Page 82: ...Mar 14 07 R Esumi D 16 ...