2. WIRING
2-15
2.7
Control Box of Hull Unit
Connect the power cable TPYCY-4 (or equivalent) and the transceiver unit cable
(10S2078) as shown below.
Confirm that the LED lights in red after wiring is completed. If the LED does not light,
turn off power from the mains switchboard, reconnect any two lines of the power cable,
turn on the power, and check if the LED lights. The hull unit does not work when this
connection is wrong.
Normal phase: LED lights (red). Phase reversal: LED does not light.
Armor
Anticorrosive
sheath
Clamp for the
transceiver unit
cable (10S2078)
LED (Red)
For detection of phase reversal
on 3-phase power cable
100
25
20
Set armor in
clamp.
Vinyl sheath
FV5.5-4
M4 (YEL) x 3
Sheath
Vinyl
sheath
Conductor
S=4 mm
2
Ø
=2.55 mm
Dimensions in
millimeters
Ø
=16.9 mm
Clamp for the
power cable
(TPYCY-4)
Summary of Contents for FSV-85
Page 28: ...1 HOW TO INSTALL THE SYSTEM 1 20 This page is intentionally left blank ...
Page 56: ...3 ADJUSTMENTS AND CHECKS 3 10 This page is intentionally left blank ...
Page 67: ...12 Nov 2010 Y NISHIYAMA D 1 ...
Page 68: ...4 Feb 2011 Y NISHIYAMA D 2 ...
Page 69: ...5 Nov 2010 Y NISHIYAMA D 3 ...
Page 70: ...4 Apr 2014 H MAKI D 4 ...
Page 71: ...6 Jul 2012 Y NISHIYAMA D 5 ...
Page 72: ...Nov 22 06 T Matsuguchi D 6 ...
Page 73: ...22 Apr 2013 Y NISHIYAMA D 7 ...
Page 74: ...22 Apr 2013 Y NISHIYAMA D 8 ...
Page 75: ...26 Nov 2010 Y NISHIYAMA D 9 ...
Page 76: ...27 Dec 2010 Y NISHIYAMA D 10 ...
Page 77: ...Nov 22 06T Matsuguchi D 11 ...
Page 78: ...D 12 ...
Page 79: ...29 Mar 2011 Y NISHIYAMA D 13 ...
Page 80: ...13 Sep 2011 Y NISHIYAMA D 14 ...
Page 81: ...13 Sep 2011 Y NISHIYAMA D 15 ...
Page 82: ...Mar 14 07 R Esumi D 16 ...