-6.2-
6.2 Advanced-level Troubleshooting
This paragraph describes how to cure hardware and software troubles which should be carried out
by qualified service personnel.
Note:
This radar equipment contains complex modules in which fault diagnosis and repair
down to component level are not practicable by users.
Serviceman qualification
All adjustments of radio transmitter during or coinciding with the installation, servicing, or
maintenance which may affect the proper operation must be performed by or under the immediate
supervision and responsibility of a person holding an operator certificate containing a ship radar
endorsement.
This is what the U.S. Codes of Federal Regulations part 80.169 implies (not exact extract).
As such, every administration sets forth its own rule; service personnel must be aware of this kind
of competency requirements.
Service call
When making a service call to your service agent, check S/N and symptom beforehand.
Problem
Probable causes or check
points
Remedy
Power turned on but radar does
not operate at all.
Control panel is not illuminated.
1 Blown fuse F1 and F2.
2 Mains
voltage/polarity
3 Power
supply
board
4 Illumination
lamps
1 Replace blown fuse.
2 Correct wiring and input voltage.
3 Replace power supply board.
4 Replace defective lamps.
CRT brilliance adjusted but no
picture.
1 CRT high tension
voltage
2 SPU
board
1 Check high tension voltage supply with
utmost care. DANGER.
2 Replace SPU board.
(
Continued on next page
)
Summary of Contents for FR-1500 MARK-3
Page 1: ...15 MULTI COLOR HIGH PERFORMANCE SHIPBORNE RADAR AND ARPA FR 1500 MARK 3 SERIES Back ...
Page 13: ...xi CONFIGURATION OF FR 1500 MARK 3 SERIES RADARS VIDEO PLOTTER RP 17 or RP 180 ...
Page 14: ...xii This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 86: ...This page is intentionally left blank ...
Page 118: ... 9 6 FR 1500 MARK 3 series interfacing diagram CHANNEL 2 OUTPUT TTM ...
Page 119: ... 9 7 ...
Page 123: ......
Page 124: ......