-2.14-
2.14 Diagnostic Sequence
You can check the ATA Board for proper operation as follows. The self test does not require
operator intervention. It runs automatically when the power is placed on at regular intervals or on
operator demand.
1. Press [MENU], [0], [0], [0], [0].
2. Press the [2] key twice to start the diagnosis sequence. The results of the test appear as
shown below.
If NG appears for any ATA-related item, call for service.
FR-1500 M-3 TEST
1. Program No. 03591521** Press MENU key to escape.
2. ROM Check
OK Press ENTER to check CRT.
3. RAM Check OK ** = Program Version No.
4. Antenna Rotation
24rpm
5. TX Trigger Frequency 3000Hz
6. Video Level
000
7. Video Signal OK
ARP TEST
1. Program No. 18590411** 18590421**
2. ROM Check
OK OK
3. RAM Check
OK
4. Speed Log
OK 0.0KT
5. Course
OK
6. Trigger
OK
7. Video Signal OK
8. Bearing Pulse OK
9. Heading Pulse OK
10. Minimum Hit OK
11. Scan Time
0274
12. Manual Acq 00
13. Auto Acq
00
14. FE-Data 1
0000
15. FE-Data 2
0000
Summary of Contents for FR-1500 MARK-3