![Furuno FMD-3200 Installation Manual Download Page 101](http://html1.mh-extra.com/html/furuno/fmd-3200/fmd-3200_installation-manual_2350123101.webp)
APPENDIX 4 ALERT LIST
AP-29
30503,31
881
Name
: ROT Gyro1 Banned
Meaning
: Heading data from No.1 ROT Gyro is deter-
mined abnormal by integrity check.
Remedy
: Reset the filter to confirm that it isn't a temporal
error value. If the data is normal, it is reusable. However, if
it's continually removed, there is a possibility that correct
data is not received from sensor. In this case, contact FU-
RUNO.
Caution/B,
TCS
30503,32
882
Name
: ROT Gyro2 Banned
Meaning
: Heading data from No.2 ROT Gyro is deter-
mined abnormal by integrity check.
Remedy
: Reset the filter to confirm that it isn't a temporal
error value. If the data is normal, it is reusable. However, if
it's continually removed, there is a possibility that correct
data is not received from sensor. In this case, contact FU-
RUNO.
Caution/B,
TCS
30503,33
883
Name
: ROT Gyro 3 Banned
Meaning
: Heading data from No.3 ROT Gyro is deter-
mined abnormal by integrity check.
Remedy
: Reset the filter to confirm that it isn't a temporal
error value. If the data is normal, it is reusable. However, if
it's continually removed, there is a possibility that correct
data is not received from sensor. In this case, contact FU-
RUNO.
Caution/B,
TCS
30403,
101
360
Name
: Lost WIND1 COM
Meaning
: Data from No.1 wind sensor has been discontin-
ued for more than set time. (Set at installation)
Default: 60 seconds
No.1 wind sensor is turned off, or there is a problem with
network.
Remedy
: Check the connection with No.1 wind sensor.
Caution/B
30403,
102
361
Name
: Lost WIND2 COM
Meaning
: Data from No.2 wind sensor has been discontin-
ued for more than set time. (Set at installation)
Default: 60 seconds
No.2 wind sensor is turned off, or there is a problem with
network.
Remedy
: Check the connection with No.2 wind sensor.
Caution/B
30403,
103
362
Name
: Lost WIND3 COM
Meaning
: Data from No.3 wind sensor has been discontin-
ued for more than set time. (Set at installation)
Default: 60 seconds
No.3 wind sensor is turned off, or there is a problem with
network.
Remedy
: Check the connection with No.3 wind sensor.
Caution/B
30403,
111
370
Name
: Lost CURRENT COM
Meaning
: Data from water current has been discontinued
for more than set time. (Set at installation)
Default: 60 seconds
Water current sensor is turned off, or there is a problem
with network.
Remedy
: Check the connection with water current and net-
work.
Caution/B
Alert No.
Alert Name, Meaning and Remedy
Priority/
Category
ALF ID
ALR ID
Summary of Contents for FMD-3200
Page 20: ...1 MOUNTING 1 10 This page is intentionally left blank...
Page 70: ...3 ECN 303 304 OPTION 3 8 This page is intentionally left blank...
Page 72: ...4 SETTING UP THE EQUIPMENT 4 2 This page is intentionally left blank...
Page 120: ...D 1 29 Nov 2017 H MAKI 29 Nov 2017 H MAKI...
Page 121: ...D 2 29 Nov 2017 H MAKI 29 Nov 2017 H MAKI...
Page 122: ......
Page 123: ......
Page 124: ...1RY 1 6 0...
Page 125: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Page 126: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Page 127: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Page 128: ...D 9 14 Jun 2018 H MAKI...
Page 129: ...D 10 14 Jun 2018 H MAKI...
Page 130: ...D 11 14 Jun 2018 H MAKI...
Page 133: ...13 Jan 2012 Y NISHIYAMA...
Page 134: ...13 Jan 2012 Y NISHIYAMA...
Page 135: ...D 16 8 Jun 2018 H MAKI...
Page 136: ...D 17 22 Aug 2019 H MAKI...
Page 137: ...D 18 6 Apr 2021 H MAKI...
Page 138: ...D 19 6 Apr 2021 H MAKI...
Page 139: ...D 20 6 Feb 2020 H MAKI...