background image

D-1

Summary of Contents for FELCOM19 Inmarsat Mini-C MES

Page 1: ...318 2 7 3 INITIAL SETTINGS 3 1 3 1 How to Install Software 3 1 3 2 How to Start Up the Software 3 3 3 3 How to Set the IMN INMARSAT MOBILE NO 3 5 3 4 How to Set up the AMS BAM 3 6 3 5 PC Window Setup...

Page 2: ...7KH SDSHU XVHG LQ WKLV PDQXDO LV HOHPHQWDO FKORULQH IUHH 85812 XWKRUL HG LVWULEXWRU HDOHU VKLKDUD FKR 1LVKLQRPL D 3 1 81 3ULQWHG LQ DSDQ OO ULJKWV UHVHUYHG 35 3XE 1R 0 0 20...

Page 3: ...ent is being installed ELECTRICAL SHOCK HAZARD 0 30 m 0 30 m 0 30 m 0 30 m Do not approach the radome closer than 0 5 m when it is transmitting Microwave radiation can cause severe injury or illness R...

Page 4: ...ANTENNA UNIT IC 119 COMMUNICATION UNIT IC 219 with internal GPS receiver POWER SUPPLY 100 115 200 230 1 50 60 Hz POWER SUPPLY 12 24 VDC AC DC Power Supply PR 240 PRINTER JUNCTION BOX IC 318 SSAS ALERT...

Page 5: ...tion Box IC 318 1 Antenna Unit IC 119 1 Antenna Bracket CP16 05602 001 189 610 1 For IC 119 Antenna Base w Hose Clamp OP16 72 001 323 420 1 Antenna Base w Mount Pipe OP16 73 001 323 430 1 Antenna Base...

Page 6: ...1 Nominal Diameter Mast Diameter For 40A I 48 6 OP16 76 2 001 443 460 1 Nominal Diameter Mast Diameter For 65A to 80A I 76 3 to 89 1 OP16 76 3 001 443 470 1 Nominal Diameter Mast Diameter For 90A to...

Page 7: ...arate the antenna unit from an S band radar as follows The allowable vibration level as specified by Inmarsat is as shown in the table be low Allowable vibration level Avoid the location near tunnels...

Page 8: ...ing the grounding stud bolt should allow the antenna ground and mast ground to be connected with the grounding cable to ground lightning strikes For de tailed measurements refer to the outline drawing...

Page 9: ...at the top for bulkhead mounting or the fixing holes at the bottom for tabletop mounting or underside of a table After mounting the unit cover the screw heads with the cosmetic caps 2 pcs sup plied t...

Page 10: ...2 m from the communication unit 1 Remove four screws from the unit to separate the bottom chassis from the top chassis 2 Fix the bottom chassis to the mounting location with four self tapping screws...

Page 11: ...cable PC CAUTION MJ A3SPF0016 035 5D FB CV NP 30 m 8D FB CV 50 m 12D SFA LITE CV 100 m Connector at one end Connector N P 5DFB N P 12DSFA N P 8DFB supplied local arrange This unit is shipped with a 10...

Page 12: ...ld back the braided shield onto the clamp and trim the shield as shown Make the length of insulator 3 5 mm and the length of the core 5 mm Be careful not to damage the core Set the center pin to the c...

Page 13: ...dimensions shown left Expose inner sheath and shield by the dimensions shown left Remove insulator and core by 10 mm Twist shield end Slip on clamp nut gasket and clamp as shown left Fold back shield...

Page 14: ...Solder them together through the hole on the pin Expose the insulator by 1 mm Expose the core by 1 mm Insert the pin into the shell Screw the clamp nut into the shell Tighten by turning the clamp nut...

Page 15: ...inyl tape Inner sheath Braided shield Armor Nut Washer Gasket Clamp Core Core Adjust the length Center pin Fold back the shield Remove the shield that hangs over the gasket Center pin Soldering Apply...

Page 16: ...nsions shown left Remove inner sheath and expose shield by the dimensions shown left Remove the insulator beneath shield by 10 mm and expose the core Slip on clamp nut washer gasket and clamp as shown...

Page 17: ...l board Procedure 1 Insert from direction 1 2 Tilt slightly toward 2 3 Insert cable core to 3 Core 7 mm 1 2 3 Vcc GND TD RD A TD RD B NC ALM H RD A NAV RD B NAV GND SSAS OUT H SSAS OUT C SSAS IN H SSA...

Page 18: ...2 WIRING 2 8 This page is intentionally left blank...

Page 19: ...and password Ask your dealer 3 1 How to Install Software After installing the equipment install the FELCOM19 software F19PC in the PC as follows 1 Turn on the PC 2 Set the CD ROM in CD drive 3 Click t...

Page 20: ...INITIAL SETTINGS 3 2 5 Enter your name and organization 6 Click the Next button 7 Click the Install button and the installation begins When the installation is com pleted the FELCOM19 dialog box appea...

Page 21: ...shortcut is created on the desktop Note To uninstall the F19 application from the PC see the operator s manual 3 2 How to Start Up the Software 1 After the software is installed open the Local Area C...

Page 22: ...1 16 1 172 31 16 3 to 172 31 16 254 Note Take care that do not use the same IP address as the default IP address 172 31 16 2 4 Establish the connection between the Communication unit and the PC with a...

Page 23: ...t and PC in order 2 Double click F19PC on the screen to start the program 3 Select the terminal FELCOM19 to use then press the Enter key The Connect window is shown on the screen Select Yes then press...

Page 24: ...Land Earth Station This arrangement is normally done by authority of VMS 3 4 How to Set up the AMS BAM Do the following to connect the AMS Alert Management System 1 Press the F8 and 1 keys to show th...

Page 25: ...ndow press the E key twice Select the appropriate BAM unit to setup The AlertIF2 Setup option window shown to the right is displayed Set the SFI for the connected BAM unit Main Menu 2 External Alarm S...

Page 26: ...l Setup menu MY SFI Setup Set SFI not used for other equipment 0001 to 9998 SFI No E Exit Enter SFI No Command Window SFI CS0001 Transmission Group Setup E Exit Enter Group No Command Window 2 TGTD 3...

Page 27: ...s after there is no key op eration To release the screensaver press any key 8 Select Window Color then press the Enter key 9 Set the window colors as follows 1 Select Preset provides three pre configu...

Page 28: ...Base Window BLACK L WHITE RCV Message Display BLACK WHITE EGC Message Display BLACK WHITE EDIT 1 BLACK WHITE EDIT 2 BLACK L CYAN Function BLACK WHITE Sub Menu 1 BLUE L WHITE Sub Menu 2 BLUE WHITE Sub...

Page 29: ...step 13 1 Select Normal or Large as appropriate Normal 800 H u600 V mm Large 1200 H u900 V mm 2 If you changed the size the message Please Restart appears Exit the PC terminal and restart the terminal...

Page 30: ...for how to switch languages 3 7 How to Use the Paper Save Function The Paper Save function allows you to choose whether to print the Successful Data Report Sending confirmation after a data report is...

Page 31: ...dard supply cable OP16 58 Code No 001 180 070 OP16 60 The IC 318 should be installed on a desktop To ensure the waterproof rating is main tained use the optional waterproofing kit OP16 60 If a floor i...

Page 32: ...001 180 110 Name Type Code No Qty Binding Screw 4 4OUNCX3 16 000 176 619 10 2 Dsub Cover 16 023 4532 100 373 520 10 1 D sub Gasket 16 023 4513 100 368 120 10 1 LAN Packing 2 16 023 4512 100 368 110 10...

Page 33: ...packing 2 16 023 4512 D sub gasket 16 023 4513 LAN waterproof plate 16 023 4531 Dsub cover 16 023 4532 Use two binding screws pre attached to fasten the LAN waterproof plate supplied with OP16 61 Use...

Page 34: ...nstalled with the cable entry facing upwards OP16 68 Code No 001 189 400 1 Unfasten four screws to remove the cover of IC 307 2 Attach supplied fixing tape to the underside of the cover as shown in th...

Page 35: ...C SEL 230 V Below a 200 230 VAC 2 2 1 7 A 1I 50 60 Hz 100 to 115 VAC SEL 115 V Below b 100 115 VAC 3 2 2 6 A 1I 50 60 Hz Remove screw and cover Cover 1 2 3 4 5 6 7 8 SEL 115V 1 2 3 100 115 VAC 1 2 3 2...

Page 36: ...5 HOW TO CHANGE POWER SUPPLY SPECIFICATIONS 5 2 This page is intentionally left blank...

Page 37: ...TYCY 4 0 75mm2 1 11mm 17 7mm TTYCY 4S 0 75mm2 1 11mm 21 1mm TTYCY 4SLA 0 75mm2 1 11mm 19 5mm TTYCYS 1 0 75mm2 1 11mm 12 1mm TTYCYS 4 0 75mm2 1 11mm 18 5mm TTYCYSLA 1 0 75mm2 1 11mm 11 2mm TTYCYSLA 4 0...

Page 38: ...6 3 5 5 167 7 21 0 7 5 6 167 7 21 0 7 5 6 3 2 80 17 5 675 7 21 25 6 59 7 9 7 21 66 6 7 67 02 1 22 127 7 21 2 80 17 23 5 725 6 0 18 1 20 23 5 725 6 0 18 1 20 23 5 725 6 0 18 3 20 23 5 725 6 0 18 3 20 2...

Page 39: ...8 0 1 7 6 0 5 4 26 10 1 3 6 70 6 06 00 70 6 5514 5 5514 5 2 1 7 06 06 00 056 4 2 6 A 2 8 0 1 7 6 0 5 4 26 10 1 3 6 70 6 70 6 10 1 056 6 10 6 4 5 056 6 10 6 4 5 2 A 3...

Page 40: ...OH 2 12 6 21 1 7 3 12 2 12 66 5 2 12 0 16 216 1 5 1 25 5 5 1 21 0 A 4 2 12 7 3 3 287 1 1 0 4 7 5 0 5 6 12 6 5 37 216 167 7 21 0 7 5 6 86 52 6 2 12 233 5 675 3 52 6 2 12 1 1 29 5 2 12 6 7 33 1 6 5 686...

Page 41: ...2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 6 2 12 7 3 63 7 0 12 1 0 2 3 3 57 287 1 12 25 3 5 6 6 7 3 5 9 9 6 63 5 25 1 48 17 7 5 0 5 6 2 12 2 12 3 6 3 12 63 5 3 576 67...

Page 42: ...D 1...

Page 43: ...D 2 19 Jan 2012 Y NISHIYAMA...

Page 44: ...D 3 17 May 2012 Y NISHIYAMA...

Page 45: ...D 4 6 Oct 2010 Y NISHIYAMA...

Page 46: ...16 Jun 2014 H MAKI D 5...

Page 47: ...26 Oct 09 R Esumi D 6...

Page 48: ...D 7 17 May 2012 Y NISHIYAMA...

Page 49: ...D 8 30 Apr 2012 Y NISHIYAMA...

Page 50: ...D 9...

Page 51: ...2 24VDC MJ A3SPF0016 035 3 5m 5A 24V 10A 12V 2 4 TTYCSLA 1 1 OR CO 0 2x2P 2 SSAS ALERT UNIT IC 307 3 2 1 4 5 6 GND SSAS_CTRL SSAS_IN C SSAS_CHECK NC SSAS_OUT H P P IC 307 3 2 1 4 5 6 No 2 P P IC 307 N...

Reviews: