3. MAINTENANCE AND TROUBLESHOOTING
37
3.5
Replacing the Fuse/Battery
If a fuse blows, find the cause before replacing it. Use only designated fuses. Using the wrong fuse
will damage the unit and void the warranty. Consult your dealer for replacement of the fuse.
A battery installed on a circuit board inside the transceiver unit preserves data when the power is
turned off. The life of the battery is about five years. When the battery voltage is low, a warning
message "Displayed time may be incorrect. Please re-set the clock." appears after the self-test.
When this happens, contact your dealer to request a replacement of the battery. Press any key to
proceed to the main display screen.
Note:
The message "Displayed time may be incorrect. Please re-set the clock." appears when the
FE-800 is turned on for the first time or after changing the battery. In this case, the battery does
not need replacement, however the clock must be set.
3.6
Troubleshooting
The table below provides simple troubleshooting procedures which you may follow to restore
normal operation. If you cannot restore normal operation, contact your dealer.
Item
Type
Code Number
Lithium Battery
BR-1225-A/BK
000-178-989-10
Glass Tube Fuse (for AC input, 2 pcs)
FGMB 250V 2A PBF
000-157-497-10
SYMPTOM
PROBABLE CAUSE
REMEDY
No picture, no
reading
measure
Low voltage
Check the supply voltage.
Fuse blown
Refer to section 3.5.
Power cable damaged
Repair the cable.
No echo
sounding
picture
Transducer cable damaged
Repair the cable.
Transducer cable connection
loosened
Tighten the connections.
Irregular
display
Low sensitivity
Increase the gain (refer to section 1.7).
Low reflectivity from seabed.
Suspect muddy seabed.
Marine life on transducer
Remove marine life from the transducer when
dry-docked.
Loss of seabed
display
Out of range
Check the range scale setting.
Air bubbles caused by going
astern or running over other
ships’ wake
This is normal. It is not a sign of equipment
trouble.
Heavy noise
Wrong installation at the
transducer
Find cause of noise. Relocate the transducer
if noise persists.
Other echo sounders nearby
If more than one echo sounder is working on
the ship, there is no ideal measure to cure the
problem.
Surface noise
Aeration in near surface water
Not an equipment problem.
Rough weather
Not an equipment problem.
“Not Connected”
appears on the
screen
Communication between the
Display Unit and Transceiver unit
is interrupted or lost
Connection(s) may be loose or disconnected.
Check the connections between the Display
Unit and Transceiver unit. Tighten loose con-
nectors and re-connected disconnected con-
nectors.