3. INITIAL SETTINGS
3-12
5. Select [Shared Settings] to open the [Shared Settings] menu.
6. Select [On] at [TX Triggering] to enable KP control with the DFF3.
Note:
The main transceiver’s [TX Triggering] setting should be [Off] while this ex-
ternal TX trigger is set [On].
7. Select [Model] at [XDCR Select].
Set the model, referring to the procedure at paragraph 3.4.1
8. Select [OK] to close the menu.
3.5
Calibration Setting
The calibration menu allows you to calibrate various settings. You can calibrate the
main system’s transducer and the external sounder’s transducer.
3.5.1
Calibration for main system transducer
1. Select the [Advanced Settings] icon (
) from the InstantAccess bar and select
the [Advanced Setting] icon (
) from the expanded menu bar.
2. Select [Calibration] from the [System] menu.
The [Calibration] menu appears.
3. Set the calibration parameters referring to the table below:
Item
Setting values
Meaning
[Temperature]
°F: -35.0 to 35.0
°C: -20.0 to 20.0
(default: 0.0)
The water temperature indication is correct-
ed. For example, if the actual temperature is
2°F higher than the temperature displayed on
screen, set the offset to [+2°F].
FCV-38[ver 0252473-xx.xx]
Summary of Contents for FCV-38
Page 8: ...EQUIPMENT LISTS vi This page is intentionally left blank ...
Page 58: ...3 INITIAL SETTINGS 3 24 This page is intentionally left blank ...
Page 66: ...D 1 9 Sep 2019 H MAKI ...
Page 67: ...D 2 3 Aug 2020 H MAKI ...
Page 68: ...D 3 3 Oct 2019 H MAKI ...
Page 69: ...D 4 26 Sep 2019 H MAKI ...
Page 70: ...D 5 14 Jun 2018 H MAKI ...
Page 71: ...D 6 14 Jun 2018 H MAKI ...
Page 72: ...D 7 14 Jun 2018 H MAKI ...
Page 73: ...D 8 Jun 10 05 ...
Page 74: ...D 9 ...
Page 75: ...Oct 22 07 R Esumi D 10 ...
Page 76: ...D 11 9 Oct 2019 H MAKI ...
Page 77: ...D 12 9 Oct 2019 H MAKI ...
Page 78: ...D 13 11 Mar 2010 Y NISHIYAMA ...
Page 79: ...D 14 15 Apr 2020 H MAKI ...