APPENDIX
AP-3
Alarm
Volume (0, 1, 2,
3
, 4, 5, 6, 7)
Bottom alarm
Alarm depth (0-10000;
0m
)
Alarm zone (1-10000:
1m
)
Fish alarm
Alarm depth (Fish: 0-10000;
0m
)
Alarm depth
(Bottom fish: 0.0-200.0;
0.0m
)
Alarm zone (Fish: 1-10000;
1m
)
Alarm zone (Bottom fish: 1.0-200.0;
1.0m
)
Temp alarm
Temp limit
(Within range, Out of range: -5.0-35.0;
20.0
°
C
)
Alarm zone
(Within range, Out of range: 0.1-30.0;
1.0
°
C
)
V-temp alarm
Temp limit
(Within range, Out of range: -5.0-35.0;
20.0
°
C
)
Alarm zone
(Within range, Out of range: 0.1-30.0;
1
.
0
°
C
)
Record
Recording setting
Recording location
Recording time (1-24;
24
(hr))
Required free space (512-32767;
1024
(MB))
Record info
Data view
Disk space info (
Time
, Size)
4
6
7
8
5
System
Output
TLL (
OFF
, ON)
Bottom discrimination (
OFF
, ON)
NMEA version (Version 1.5,
Version 2.0
, Version 3.0)
Compensation
Stabilization (OFF,
ON
)
Heave (OFF,
ON
)
Sound veolocity (1400-1600;
1500m/s
)
Draft (-6.0-60.0;
0.0m
)
Roll offset (-10.0-10.0;
0.0
deg
)
Pitch offset (-10.0-10.0;
0.0
deg
)
Motion sensor (SC,
Internal sensor
)
SC-TD in longitudinal dir (-100.0-100.0;
0m
)
SC-TD in port/stdb dir (-100.0-100.0;
0m
)
SC-TD in up/down dir (-100.0-100.0;
0m
)
Internal sensor in bow dir (0-360;
0 deg
)
Temp
Temp input (CIF,
NMEA
)
Temp adjust (-20.0 to 20.0,
0
)
Net
Input data (CIF,
NMEA
)
V-temp graph
Horizontal axis (Min) (-5.0-35.0;
-5.0
°
(C))
Horizontal axis (Max) (-5.0-35.0;
-35.0
°
(C))
(Measurement)
(Unit)
Fish gain (-12.0-12.0;
0
)
Measurement threshold (2-20;
4
(cm))
Measuring area (Manual, All, Specific range, Bottom trace)
Manual area (Vertical) (10-100;
10
(%))
Manual area (Horizontal) (10-100;
10
(%))
Bottom trace area (2m, 5m,
10m
, 20m, 50m, 100m, 200m)
Calibration value (-30.0-30.0;
0
(db))
Unit (TS,
L(cm)